6TANTP513-1E
TOTAL ACCESS
3000/3010
NTP-513
Page 7 of 8
Perform Steps Below in the Order Listed
For Details Go To:
Total Access
®
3000/3010 Systems Manual
© 2002, ADTRAN, Inc.
NOTE
There is no provisioning required at the HTU-Rs to remove protection-
switching capability. Upon completion of the above procedure, the MAIN
circuit is an independent, non-protected HDSL circuit. The AUX circuit is
also now independent, with protection switching disabled, and currently
OOS-U
.
1.6.2
Adjust wiring at Dual remote housing
Once protection switching has been disabled in the HTU-Cs, the housing is internally
wired to provide a DS1 signal to both the MAIN DS1 and AUXILIARY/TEST DS1
RJ-48 jacks. Connect the customer’s equipment to the AUX RJ-48 jack or the AUX
DS1 terminal strip in the housing to complete a second independent HDSL circuit.