Total Access
®
3000/3010 System Manual
6TAATP602-1E
TOTAL ACCESS 3000/3010
ATP-602
Page 5 of 6
© 2002, ADTRAN, Inc.
B.
Verify the pulse amplitude of the positive peak is b0.36 and
+0.85v peak.
C.
Verify the pulse amplitude of the negative peak is between –0.36 and
-0.85v peak.
D.
Verify the ratio of the positive to negative isolated pulses are between
0.90 and 1.10.
1.2.1
Followup Procedures
Once this procedure is complete, the Total Access 3000/3010 shelves should be ready
for installation of access modules. These access module NTPs and DLPs are in the
production process and will be added to the manual upon completion. Please refer to
the Installation and Maintenance practice for the specific module for the installation
instructions.