Total Access
®
3000/3010 System Manual
6TADLP717-1E
TOTAL ACCESS 3000/3010
DLP-717
Page 2 of 4
© 2002, ADTRAN, Inc.
Perform Steps Below in the Order Listed
1.2
Detailed Level Procedure 717
1.2.1
To set the Target ID (TID) in the system:
1.
Logon to the system
2.
From the Total Access 3000/3010 main menu, select option 1, System
Controller, and press <Enter>.
3.
From the System Controller menu, select option 2, Provisioning, and press
<Enter>.
4.
From the Provisioning menu, select option 5, TL1, and press <Enter>.
5.
From the TL1 menu, select option 2, Target ID, and press <Enter>.
6.
Enter the 11 character Target ID and press <Enter>.
The Target ID issued from TIRKS will be an 11 digit code similar to the following
format: HTVLALEXD01
Where:
HTVL
designates the city
AL
designates the state
EX
identifies the Central office or remote terminal
D
identifies equipment type (“D” is administrative equipment)
01
identifies the piece of equipment of that type at the CO
7.
Press <Esc> to return to the main menu.
1.2.2
To set the Shelf Number, continue with the following:
1.
From the Provisioning menu, select option 5, TL1, and press <Enter>.
2.
From the TL1 menu, select option 1, Shelf Number/Shelf ID, and press
<Enter>.
3.
Input the Shelf Number and press <Enter>.
NOTE
The Shelf Number is a numerical value between 1 and 254 (inclusive) and is
used to identify the shelf as distinct on the RS-485 bus. Only 16 shelves are
supported on a single RS-485 bus; therefore, there should not be matching
Shelf Numbers on the same RS-485 bus.
4.
Press <Esc> to return to the main menu.