Total Access
®
3000/3010 System Manual
6TADLP726-1E
TOTAL ACCESS 3000/3010
DLP-726
Page 2 of 6
© 2002, ADTRAN, Inc.
Perform Steps Below in the Order Listed
1.2
Detailed Level Procedure 726
1.Connect to the SCU’s Craft Interface
If you are not already connected to the Host SCU’s craft interface either with a
VT100-compatible terminal or with a PC running VT100 emulation software, use
the procedure in DLP-716 to connect to the craft interface.
2.Logon to the SCU
Use the READ_WRITE account name and password to logon to the SCU.
3.Go to the T1 Menu
3.1
From the main menu, select option 1, System Controller, and press <Enter>.
3.2
From the System Controller menu, select option 2, Provisioning, and press
<Enter>.
3.3
From the Provisioning menu, select option 5, TL1, and press <Enter>.
4.Choose the Enter TL1 Command Option
Choose menu option 3 from the TL1 Menu to get to the TL1 command input
prompt.
5.Retrieve the X.
25 Status
Issue the following command to retrieve the X.25 status:
rtrv-stat-x25:::1;
6.Verify that the X.
25 Status is Correct
Verify that the response is of the form:
<CLLI Code> <date> <time>
M 1 COMPLD
/* Link status 0x50 */
/* Frame status 0x0 */
/* Server 0 status 104 user ‘’ */
/* Server 1 status 104 user ‘’ */
/* Server 2 status 104 user ‘’ */
/* Server 3 status 104 user ‘’ */
/* Server 4 status 104 user ‘’ */