6TADLP730-1E
TOTAL ACCESS 3000/3010
DLP-730
Page 2 of 6
© 2003, ADTRAN, Inc.
Total Access
®
3000/3010 System Manual
1.1.2
Prerequisite Procedures
The following procedures must be completed prior to configuring the SCA system in
the SCU. If necessary, refer to the appropriate documentation before proceeding. The
prerequisite procedures include:
•
Installation and wiring of a Total Access 3000/3010 shelf and SCU –
•
Physical installation of the Multiplexer Module(s) to be used (necessary if
implementing the in-band management channel for IP or SNMP traffic):
•
Verifying SCU Communications over an IP LAN –
•
Proper installation and connection of a TFTP server
•
1.2
Detailed Level Procedure 730
1.2.1
Configure the TFTP Server Address
1.
From the Total Access 3000/3010 main menu, select System Controller, and
press <Enter>.
2.
From the System Controller main menu,
select Provisioning
, and press
<Enter>.
3.
From the Provisioning menu, select
SCU/System Administration
, and press
<Enter>.
4.
From the SCU/System Administration menu, select
System Configuration
Archive (SCA), and press <Enter>.
5.
From the System Configuration Archive (SCA) menu, select
SCA Operations
,
and press <Enter>.
6.
From the SCA Operations menu, select
SCA TFTP Server
, and press <Enter>.
This field holds the IP address or hostname of the TFTP server that holds the saved
SCA files.
7.
Enter the IP address or hostname of the TFTP server that holds the saved
SCA files.
8.
Return to the System Configuration Archive (SCA) menu by pressing <Esc>.
Perform Steps Below in the Order Listed