Total Access
®
3000/3010 System Manual
6TADLP740-1E
TOTAL ACCESS 3000/3010
DLP-740
Page 4 of 10
© 2003, ADTRAN, Inc.
Perform Steps Below in the Order Listed
NOTE
In a protection configuration, it is recommended to ‘Enable’ Linked
Provisioning so that the Protect MUX is automatically provisioned with the
identical settings as the Working MUX.
NOTE
The DS-3 Line Code parameter is hard-coded to B3ZS and cannot be changed.
5. Return to the Working MUX Main Menu by pressing <Esc> and proceed to the
next section.
1.4
Performance Monitoring Provisioning
Performance monitoring options can be set to enable the module to capture
performance monitoring data. Alarm thresholds for various alarm conditions are set
and, when exceeded, issue an appropriate alarm. To set alarm threshold values perform
the following.
1. From the Working MUX Main Menu select option 6,
Performance Monitoring
,
and press <Enter>.
2. From the Performance Monitoring Menu select option 5,
Daily Threshold
, and
press <Enter>.
Options 5-8 are able to have alarm thresholds set. Options 5 and 6 will be shown
here. Options 7 and 8 are identical in the different alarms they contain.
1.
Code Violation ........................... L
2.
Errored Second ......................... L
3.
Code Violation ........................... P-P
Definitions
4.
Code Violation ........................... CP-P
L, -L – Line
5.
Errored Second ......................... P-P
P, -P – Path
6.
Errored Second ......................... CP-P
P – P-bit parity
7.
Severley Errored Second .......... P-P
CP – C-bit parity
8.
Severley Errored Second .......... CP-P
9.
Unavailabe Second .................... P-P
10. Sev Errored Frame Second ...... P
11. Protection Switch Count