6TADLP742-1E
TOTAL ACCESS 3000/3010
DLP-742
Page 2 of 14
© 2003, ADTRAN, Inc.
Total Access
®
3000/3010 System Manual
Perform Steps Below in the Order Listed
Linked Provisioning only applies to MUX modules and transfers provisioning data
from one MUX to the replacement MUX. Unlike Auto-Provisioning, Linked-
Provisioning does not transfer the Service State of the current MUX to the replacement
MUX. Linked-Provisioning can be set from either MUX module and is either enabled
on both units or disabled on both units.
NOTE
When both Auto and Linked Provisioning are enabled, the unit will get its
provisioning settings through Linked-Provisioning. Hence, the replacement
unit will not receive Service State information and will have to be manually
placed in the appropriate Service State.
The module must first be placed in the OOS, Maintenance service state before
provisioning can take place. Follow the procedure below to place the module in the
OOS, Maintenance state.
1.2.1
Place the Module in Out-of-Service, Maintenance State
Logon to the system
1. From the System Controller Menu select option 2,
Common A – [OC-3MX]
, and
press <Enter>.
2. From the Primary MUX Menu select option 2,
Provisioning
, and press <Enter>.
3. From the Provisioning Menu select option 1,
Service State
, and press <Enter>.
4. From the Service State Menu select option 2,
Out-of-Service
,
Maintenance
and
press <Enter>.
5. Return to the Primary MUX Provisioning menu by pressing <Esc> and proceed
to Section 1.3.
1.3
Provisioning the Primary MUX
The following procedure includes each provisioning item and a brief description of
each.