Total Access
®
3000/3010 System Manual
6TADLP743-1E
TOTAL ACCESS
3000/3010
DLP-743
Page 1 of 4
© 2003, ADTRAN, Inc.
Perform Steps Below in the Order Listed
Configuring a Multiplexer Module for APS Operation
1.1
Introduction
This section provides step-by-step instructions for the APS configuration of a Total
Access 3000 MUX module. Instructions are included for the DS3, STS-1 and OC-3
Multiplexer Modules.
1.1.1
Prerequisite Procedures
Before beginning the configuration procedure described in this DLP, the user should
ensure that a Total Access 3000 shelf is properly installed and wired for the respective
MUX operation. Also, ensure the SCU is installed and provisioned. Refer to
Shelf Installation in a Central Office
, for detailed procedures for either of the above
applications.
1.1.2
Tools and Materials Required
• Total Access 3000 chassis installed and wired with SCU.
• Two Total Access 3000 (DS3, STS-1 or OC-3) Multiplexer Modules