1.1
Provisioning the OC-3 Multiplexer Module
NOTE
References to common, but differing, parameters between the Total Access
3000 and the Total Access 3010, such as number of slots, will be conveyed
by the convention a/b. “A” represents the Total Access 3000 parameter and
“b” represents the Total Access 3010 parameter. For example, the differing
number of access slots in the two platforms, 28 for the Total Access 3000 and
22 for the Total Access 3010, would be displayed “28/22.”
1.1.1
Introduction
This section provides step-by-step instructions for the provisioning of a Total Access
3000/3010 OC-3 MUX module. In the case of 1:1 protection, instructions are included
for the provisioning of the working and protect modules.
1.1.2
Prerequisite Procedures
The following procedures must be completed prior to provisioning the OC-3 MUX
module and are assumed to have been completed. If necessary, refer to the appropriate
documentation before proceeding. The prerequisite procedures include:
•
Installation and wiring of Total Access 3000/3010 shelf and SCU – NTP-501
•
Physical installation of OC-3 MUX Module – NTP-506
1.1.3
Tools Required
A pen or pencil will be required to operate the recessed APS button on the faceplate of
the unit.
1.1.4
Materials Required
•
Total Access 3000/3010 OC-3 MUX module (2 modules for 1:1 protection
switching applications)
Perform Steps Below in the Order Listed
1.2
Preparing to Provision the Primary MUX (slot A)
NOTE
If MUX Auto-Provisioning is enabled in the SCU and an OC-3 MUX unit is
subsequently removed and replaced with another OC-3 MUX unit, the SCU
will automatically download the provisioning settings, including Service
State, to the replacement OC-3 MUX.