1.6.4
Fiber Applications
All fiber optic cable connections in Total Access 3000/3010 are made directly on fiber
optic access modules or multiplexer modules. Fibers are routed through the gap
between the top of the shelf and the top of the fiber card faceplate once a fiber optic
card is installed.
The Heat Baffle/Fiber Routing Tray (1181003L1) is recommended for all systems that
will incorporate any fiber optic multiplexers or access modules. This multifunction
unit, which also channels heat away from units above the system and provides for
mounting a Fan Unit, provides access and management for routing fiber optic cables
into/from a system installed immediately below it. Fiber can be routed either through
the sides or the back of the Heat Baffle/Fiber Routing Tray. The front cover, which
protects installed fiber, must be removed to install fiber optic cable or to change an
existing installation of fiber optic cable. Installation of the Fan Module to the rear of
the Heat Baffle/Fiber Routing Tray does not affect fiber optic cable routing in this unit.