6TAENG201-1E
TOTAL ACCESS 3000/3010
ENG-201
Page 29 of 32
Total Access
®
3000/3010 System Manual
© 2002, ADTRAN, Inc.
1.7
Local Loop Connections for TDM Applications
Total Access 3000/3010 supports two types of local loop connections: copper pair and
optical fiber. All local loop connections are serviced through access modules.
1.7.1
Copper Loop Support
Copper pairs in Total Access 3000/3010 are delivered through 64-pin/50-pin AMP
Champ connectors on the backplane. Each slot has access to a total of eight copper
pairs, two of which are generally reserved for a DSX-1 network interface. Each of the
eight 64-pin/50-pin AMP Champ connectors delivers a single copper pair to each of
the 28 access module slots in the system.
The AMP Champs on the backplane are designated as follows: Pairs 1 through 4 are
generally local loop copper pairs. Pairs 5 and 6 can be a single DSX-1 network
interface (DSX-1 “B”) or local loops. Pairs 7 and 8 are generally reserved for DSX-1
for each slot (DSX-1 “A”). See
Figure 13
and
Figure 14
for the layout of backplane
AMP Champ connectors for the Total Access 3000/3010.
This configuration supports the DSX-A as being dedicated, while Pairs 5 and 6 can be
routed to either the DSX
or
to the MDF.
Figure 14. Eight AMP Champ Connectors with Associated Labels for the
Total Access 3010
134
134
Pair 1
Pair 2
Pair 3
Pair 4
Pair 5
Pair 6
Pair 7
Pair 8
2298
J34
MDF
MDF
MDF
MDF
MDF or DSX-1 "B"
MDF or DSX-1 "B"
DSX-1 "A"
DSX-1 "A"
Figure 13. Eight AMP Champ Connectors with Associated Labels for the
Total Access 3000
O
N
2298
J34
TERM
IN
TERM
OUT
Pair 1
Pair 2
Pair 3
Pair 4
Pair 5
Pair 6
Pair 7
Pair 8
MDF
MDF
MDF
MDF
MDF or DSX-1 "B"
MDF or DSX-1 "B"
DSX-1 "A"
DSX-1 "A"