Total Access 850 System Manual
Section 4 User Interface Guide
64203376L1-1B
© 2004 ADTRAN, Inc.
87
S
YSTEM
C
ONFIG
> N
ETWORK
T
IME
Activate the network time and configure the server type, time zone and various other network time
parameters from this menu.
S
YSTEM
C
ONFIG
> N
ETWORK
T
IME
> S
ERVER
T
YPE
The unit time can be entered manually from the
S
YSTEM
I
NFO
menu, or the unit can receive time from an
NTP/SNTP server. The
N
ETWORK
T
IME
menu includes all parameters relating to how the unit
communicates with the time server.
The server type defines the port on which the unit will listen to receive timing information from the time
server. The choices are
NT T
IME
and
SNTP
. When set to
NT T
IME
, the unit will receive time from an NT
server running SNTP software on its TIME port. When set to
SNTP
, the unit will receive time directly
from an SNTP server. The factory default is
SNTP
.
S
YSTEM
C
ONFIG
> N
ETWORK
T
IME
> A
CTIVE
This network timing feature can be turned on and off. It determines whether the unit will request and
receive time from a time server. The factory default is
N
O
.
S
YSTEM
C
ONFIG
> N
ETWORK
T
IME
> T
IME
Z
ONE
All time zones are based off of Greenwich Mean Time (GMT). The choices are listed below.
•GMT
•GMT -5 (E
ASTERN
)
•GMT -6 (C
ENTRAL
)
•GMT -7 (M
OUNTAIN
)
•GMT -8 (P
ACIFIC
)
•GMT -9 (A
LASKA
)
•GMT -10 (H
AWAII
)
The factory default is
GMT-6 (C
ENTRAL
)
.
S
YSTEM
C
ONFIG
> N
ETWORK
T
IME
> A
DJUST
FOR
D
AYLIGHT
S
AVING
Since some areas of the world use Daylight Savings Time, the unit is designed to adjust the time on the
first Sunday in April and the last Sunday in October accordingly if this option is turned on. The factory
default is
Y
ES
.
S
YSTEM
C
ONFIG
> N
ETWORK
T
IME
> H
OST
A
DDRESS
This is the IP address of the time server that the unit will request and receive time from. The factory default
is no entry in the host address field.
S
YSTEM
C
ONFIG
> N
ETWORK
T
IME
> R
EFRESH
This is the interval of time between each request the unit sends out to the time server. A smaller refresh
time guarantees that the unit receives the correct time from the server and corrects possible errors more
quickly. This may be more taxing on the machine. A range of refresh times is available for the user to
decide which is best for their unit. Choices include
5
MINS
, 10
MINS
, 15
MINS
, 20
MINS
, 25
MINS
, 30
MINS
, 35
MINS
, 40
MINS
, 45
MINS
, 50
MINS
, 55
MINS
,
and
60
MINS
. The factory default is
60
MINS
.
Summary of Contents for Total Access 850
Page 14: ...Table of Contents Total Access 850 System Manual 14 2004 ADTRAN Inc 64203376L1 1B ...
Page 16: ...Section 1 System Description Total Access 850 System Manual 16 2004 ADTRAN Inc 64203376L1 1B ...
Page 22: ...Section 1 System Description Total Access 850 System Manual 22 2004 ADTRAN Inc 64203376L1 1B ...
Page 224: ...Section 5 DLP 4 Total Access 850 System Manual 224 2004 ADTRAN Inc 64203376L1 1B ...
Page 232: ...Section 5 DLP 6 Total Access 850 System Manual 232 2004 ADTRAN Inc 64203376L1 1B ...
Page 236: ...Section 5 DLP 7 Total Access 850 System Manual 236 2004 ADTRAN Inc 64203376L1 1B ...
Page 244: ...Section 5 DLP 10 Total Access 850 System Manual 244 2004 ADTRAN Inc 64203376L1 1B ...
Page 252: ...Section 5 DLP 13 Total Access 850 System Manual 252 2004 ADTRAN Inc 64203376L1 1B ...
Page 256: ...Section 5 DLP 14 Total Access 850 System Manual 256 2004 ADTRAN Inc 64203376L1 1B ...
Page 264: ...Section 5 DLP 16 Total Access 850 System Manual 264 2004 ADTRAN Inc 64203376L1 1B ...
Page 278: ...Section 6 ADTRAN Utilities Total Access 850 System Manual 278 2004 ADTRAN Inc 64203376L1 1B ...