DS3 Alarm Traps (Far-End Active Cards)
Trap
If enabled, the unit issues a trap when...
LOS
the remote unit’s active controller card has lost
the network Rx signal.
OOF
the remote unit’s active controller card detects
a framing loss from the network.
AIS
the remote unit’s active controller card is re-
ceiving an AIS (blue) alarm condition from the
network.
RAI
the remote unit’s active controller card is re-
ceiving an RAI (yellow) alarm from the network.
This alarm is a signal sent back toward the
source of a failed transmit circuit. The X-bits
(X1 and X2) are set to zero.
IDLE
the remote unit’s active controller card detects
an idle sequence from the network. Service is
immediately available for use.
DS3 Eqpt Fail
SA
the remote unit’s active controller card is re-
ceiving a service-affecting equipment failure
message from the network.
DS3 Eqpt Fail
NSA
the remote unit’s active controller card is re-
ceiving a non-service-affecting equipment fail-
ure message from the network.
Comn Eqpt Fail
NSA
the remote unit’s active controller card is re-
ceiving a common equipment failure message
from the network.
Summary of Contents for TOTAL ACCESS MX2800
Page 8: ...viii MX2800 User Manual 61200290L1 1...
Page 16: ...List of Tables xvi MX2800 User Manual 61200290L1 1...
Page 100: ...Chapter 7 Circuit and Network Redundancy 7 6 MX2800 User Manual 61200290L1 1...
Page 106: ...Chapter 8 Power Loss Recovery 8 6 MX2800 User Manual 61200290L1 1...
Page 110: ...Appendix A Pinouts A 4 MX2800 User Manual 61200290L1 1...
Page 114: ...Appendix B Specifications Summary B 4 MX2800 User Manual 61200290L1 1...
Page 130: ...Appendix D Glossary D 12 MX2800 User Manual 61200290L1 1...
Page 140: ...Index Index 10 MX2800 User Manual 61200290L1 1...
Page 142: ......