Chapter 7. Circuit and Network Redundancy
7-2
MX2800 User Manual
61200290L1-1
NON-REDUNDANT MODE
In Non-Redundant Mode, the MX2800 houses only one controller
card and only one network connection is available. There is no
failure protection. In the event of a failure, an alarm is initiated and
the front panel LEDs reflect the condition. See Figure 7-1 for an
illustration.
Figure 7-1. Non-Redundant Mode
In this mode, the DS3 must be connected to the
IN
and
OUT
jacks for
DS3 A
.
Summary of Contents for TOTAL ACCESS MX2800