Section 4 Network Turnup Procedure
TRACER 6000 Series Split System Manual
54
Copyright © 2005 ADTRAN, Inc.
612806320L1-1B
Quad E1 (75
Ω
) Module Interfaces
The physical E1 interfaces are provided using a single DB-25 interface, an adapter cable, and a BNC
breakout panel. Connect one end of the adapter cable (labeled
TO RADIO
) to the module’s DB-25
connector, and then attach the other end of the cable (labeled
TO PANEL
) to the BNC breakout panel. The
75
Ω
unbalanced interfaces provided by the breakout panel are available for connection to standard E1
DTE devices (see Figure 6).
Figure 6. E1 Connection with Breakout Panel
Quad Ethernet Switch Module
The physical Ethernet interfaces are provided using four RJ-45 jacks. Ethernet cables are not supplied with
your shipment. Connect any standard Ethernet device to one of the switch ports located on the rear of the
unit.
1
2