Chapter 2. Installation
34
TSU 120 User Manual
61200.129L1-1
Set Unit Identification Number
The Unit ID sets the unit to respond to remote control
(controlled by a device other than the front panel). If
no Unit ID is recorded it is not possible to operate
from any remote control device, including the local
PC.
To Set the Unit Identification
In the Unit ID menu (item 4) under the UTIL menu,
enter any value between 2 and 250. The number 1 is
reserved for the PC.
Pressing Enter records the Unit ID number and
establishes its availability for operation by remote
control. The unit proceeds to the Set Control Port
prompt.
No Unit ID Desired
Without entering any numbers at the Unit ID menu,
press Enter. Pressing Enter with no Unit ID recorded
establishes the unit as not able to be operated by
remote control.