Chapter 4. Example Operations
104
TSU 600 User Manual
61200.076L2-1
The results of this check are shown under submenu
item 4)PATTERN RESULTS (see Figure 4-19).
*
Figure 4-19
Test Pattern Results Display
The Test Pattern Results are explained in the following
discussion :
ES
The number of seconds with at least 1
bit error.
BES
The number of seconds with more than
1 bit error and less than 320.
SES
The number of seconds with more than
320 bit errors.
*
The pattern sync has been lost.
No (Yes)
Current pattern sync status. Indicates if
pattern sync is
(Yes
), or is not (
No
),
valid.
Pressing the
2
key results in injecting errors.
Clear the results with the
Clear
key (shift 9).
If not in pattern sync, the TSU does not accumulate errored
seconds.
When through viewing the results,
Cancel
returns the
unit to submenu item 3)TEST PATTERN. Select
None
to terminate the test and the QRSS pattern generation.
The far end will still be in loopback until the network
REMOTE LOOPBK is set to
None
under submenu
item 2)REMOTE LOOPBK.