Chapter 3. Operation
61200.076L2-1
TSU 600 User Manual
81
*
Figure 3-21
Test Pattern Results Display
ES
The number of seconds with at least 1
bit error.
BES
The number of seconds with more
than 1 bit error and less than 320.
SES
The number of seconds with more
than 320 bit errors.
*SYNC
Indicates if pattern sync is, (yes) or is
not, (no) valid. The asterisk (
*
)
indicates if pattern sync has been lost
since the start of testing.
Results can be cleared by pressing
Clear
(
shift 9
).
The results are accumulated until the test pattern is set
to
None
or
Cleared
.
The use of TST DS0s for testing can be very useful,
particularly in Fractional T1 applications. An end to end
test can be run on the Fractional DS0s by 1) setting for
Map B the TST in the same DS0 as used by Map A to
receive data from an Nx56/64 port and 2) by looping the far
end using a V.54 loopback code on the Nx56/64 port. In
addition, a single DS0 can be used for continuous testing
while other DS0s are passing normal data. This will also
provide an end to end check on the entire link. Set each end
to send QRSS in TST DS0s (using 1 DS0) and occasionally
view the results on the Pattern Result menu selection.
Summary of Contents for TSU 600
Page 1: ...61200 076L2 1B July 1997 TSU 600 USER MANUAL Part Number 1200076L2 1200076L2 DC...
Page 4: ...Table of Contents...
Page 96: ...Chapter 3 Operation 84 TSU 600 User Manual 61200 076L2 1...
Page 118: ...Chapter 4 Example Operations 106 TSU 600 User Manual 61200 076L2 1...
Page 126: ...Appendix C System Configuration Charts 114 TSU 600 User Manual 61200 076L2 1...
Page 128: ...Appendix D TSU 600 System Messages 116 TSU 600 User Manual 61200 076L1 1...