The pipe with external supply of combustion air can be taken out at the bottom of the back side of the stove
or under the stove (see illustration below)::
Using the stove without external air supply
If you want to use the wood burning stove without connecting the supply of combustion air, break off the
cover plate in the rear cover at the bottom of the back of the stove. Otherwise, there is not enough air for the
combustion.
In very well-insulated houses, or houses with powerful cooker hoods and/or air conditioning systems, a
vacuum can be created around the wood burning stove, leading to smoke leakage and poor combustion. In
these circumstances, it might be necessary to open a window to provide air for the combustion and to
equalize the vacuum. Alternatively, you could place an air vent in the room where the wood burning stove is
placed.
2.5.1 Installation options
Indirect through
external wall
Through floor
and foundation
Through
wall
Trough floor and
crawl space
Aduro 15 Lux
Aduro 12