To secure access to inspection openings and enough air for the combustion, there needs to be a distance of
at least 8 cm to the wall behind and 60 cm to the side. You must be prepared to dismount the flue pipe and
turn the stove during the yearly inspection and by maintenance.
If the Aduro H1 & H3 LUX is to be placed close to flammable material such as a wooden floor or carpet it
must be placed on a non-flammable base. The floor plate should extend for at least 30 cm in front of the
Aduro H1 & H3 LUX and 15 cm on each side
– measured from the combustion chamber opening.
2.2 Pipe connection
Aduro H1 & H3 LUX leaves the factory with the flue outlet mounted on the top. If you require the flue outlet
on the back, remove the round circle from the rear cover at the upper rear of the stove and then exchange
the exhaust connector (located on the top outlet above the stove) with the cover plate (that covers the rear
outlet). The top outlet is finished with the plate that lies in the ash pan. We recommend that you place a thin
gasket between the flue pipe and exhaust branch. A flue pipe with an internal diameter of 150 mm should be
used for Aduro stoves. Aduro H1 & H3 LUX is tested and approved for use with an uninsulated fluepipe of
minimum 100 cm.
The Aduro H1 & H3 LUX must be installed on a floor with the adequate load-
bearing capacity. If the existing construction does not meet this requirement,
appropriate adaptation measures must be taken (e.g. a load-distributing plate).