3. Lighting a fire in the Aduro H1 & H3 LUX
You can light the fire using just pellets or light it manually with wood
– or a combination where you put
firewood in the combustion chamber and use the pellets to light the fire.
Important safety information
•
The Aduro H1 & H3 LUX will become warm during use and therefore it should be treated with all
necessary caution.
•
Never keep easily combustible fluids such as petrol in the near of the Aduro H1 & H3 LUX.
•
Never use easily combustible fluids to light the fire in the Aduro H1 & H3 LUX.
•
When lighting a fire, it is important to get the fire burning fast. If the fire does not start quickly and
wood only smoulders, it can cause strong smoke formation and in worst case cause an explosive
ignition of the flue gasses, which can damage the stove.
•
Never empty the ash pan when the Aduro H1 & H3 LUX is warm. Embers may still be found in the
ash pan for up to 24 hours after the fire has gone out. Please wait to empty the ash pan until you
are sure that there are no embers in the ash.
•
The door should be kept closed while the Aduro H1 & H3 LUX is in use. While lighting the fire, the
door can stand ajar for the first few minutes.
•
The pellet function stops if the door is opened.
•
When putting logs in a hot stove, you must always open the primary air intake and make sure that
the wood ignites within 2-3 minutes. If the wood does not ignite, add some ignition products and
ignite them manually.
•
In the event of a chimney fire: Close all the dampers on the Aduro H1 & H3 LUX and call the fire-
fighting service.
3.1 Damper
The stove is equipped with a damper under the door, which regulates the combustion air: primary,
secondary, and tertiary air supply. The primary air is used at the beginning to get the fire going, the
secondary air keeps the fire burning evenly, and the tertiary air ensures that flue gasses are burned. You
must always add secondary and tertiary air, while firing the stove. According to our experiences regarding
the use of the pellet function, we recommend that the damper is always completely closed to achieve the
optimum combustion of the pellets.
The damper allows you to adjust the Aduro H1 & H3 LUX according to the chimney draft and the heat output,
you require. The longer the damper is pulled out, the more air is added and the more powerful the
combustion. The illustration below shows the stove seen from the front with the dampers indicated. Use
edge of door to read position of inlet air:
1: Fully open primary, secondary, and tertiary air inlet. This
position can be maintained with the Aduro key, which must be
placed in the two holes.
2: Closed primary air inlet, fully open secondary and tertiary air
inlet.
3: Closed primary air inlet, half way closed secondary air inlet
and fully open tertiary air inlet.
4: Closed primary and secondary air inlet, fully open tertiary air
inlet.
5: Regulator pushed all the way in. All air inlet closed (only
used when burning wood pellets).
Summary of Contents for EN13240