5. Control of Aduro H1 & H3 LUX
Aduro H1 & H3 LUX has the following ALARM modes where pellet delivery must be stopped immediately:
•
SMOKE SENSOR: smoke sensor defect.
•
SHAFT SENSOR: shaft sensor defect.
•
TERMO: shaft sensor too hot.
•
DOOR CONTACT: door open.
•
PELLET DAMPER: damper closed.
•
EXIT: defect exit for external auger.
•
FUEL: smoke temperature too low after more than an hour of operation
– no fuel?
•
LIGHTING: smoke temperature not reached after two attempts to light the fire.
•
CO: CO (carbon monoxide) level is too high.
Here the
ALARM
will light red. When the cause of alarm has been rectified, the stove can be started by
pushing
ON/OFF
twice.
The development within phones and electronics continuously provides new possibilities and demands for
updates and developments of the app. When you buy an Aduro Hybrid stove, updates of the app and control
system are included 5 years after purchase. After this, charges may apply for updates.