2.2 Pipe connection
Please ensure that all local rules and regulations are complied with, including CE marking of the flue pipe.
Additionally, distance requirements to flammable material for the pipe must be respected.
All Aduro hybrid stoves use a flue pipe with an internal diameter of 150 mm. Aduro Hybrid stoves are tested
and approved for use with an uninsulated flue pipe of minimum 100 cm.
The stove leaves the factory with the flue outlet mounted on the top. If you require the flue outlet on the back,
break off the cover plates positioned at the top of the back of the stove. Exchange the exhaust connector
(from the top outlet) with the cover plate from the rear outlet. Mount the cover plate from the rear outlet to the
top outlet. The top outlet is finished with the plate that lies in the ashpan. We recommend putting a slim
gasket between the flue on the stove and the flue pipe.
2.3 Connection to a brick chimney
If the stove is being connected to a brick chimney you should use the rear outlet or a curved flue pipe via the
top outlet. After measuring, a hole is made in the chimney in which the pipe sleeve is placed, and stove
mortar is used to seal it in place. The stove is placed in position, and the flue pipe is put in place. A thin
gasket is placed between the flue pipe and the pipe sleeve to seal the joints. The flue pipe should protrude
into the pipe sleeve but must not block the opening in the chimney (see the illustration below). We
recommend putting a slim gasket between the flue on the stove and the flue pipe.
The hybrid stove can be connected to a chimney to which other heat sources are connected.
2.4 External air supply
All wood burning stoves need constant supply of air to ensure a clean and efficient combustion. This is often
a problem in modern energy-efficient houses that are very tight. Therefore, all Aduro hybrid stoves are
equipped with external air supply, where the air for the combustion is supplied from the outside and directly
into the stove. The external air duct is connected to the connecting pipe at the back of the stove (see
illustration). The amount of air needed for combustion is 25 m3/h. Air vents must be positioned where they
cannot be blocked.
The hybrid stove must be installed on a floor with the adequate load-bearing
capacity. If the existing construction does not meet this requirement,
appropriate adaptation measures must be taken (e.g., a load-distributing plate).