71
Small flame and overflown brazier = the chimney draft is not sufficient
Aduro hybrid stoves come with standard settings regarding e.g., the speed of the augers and the
performance of the fan. To achieve the most efficient pellet combustion it may be necessary to adjust these
settings to match your specific installation and your chimney draft.
You can partly compensate for a poor chimney draft by increasing the fan speed on the hybri
d stove’s three
heat levels.
•
You can adjust this in the app by pressing the gear icon on the home page:
•
Now press ”Adjust”:
•
Unlock the settings by pressing the lock icon in the top right corner:
It may also be necessary to reduce the chimney draft with a flue damper or increase the draft with a smoke
exhauster, e.g.
6. Important alarms
Aduro hybrid stoves have these following alarms, where the pellet supply must be stopped immediately:
•
SMOKE SENSOR: The smoke sensor is defect.
•
SHAFT SENSOR: The shaft sensor is defect.
•
TERMO: The shaft sensor is too hot.
•
DOOR CONTACT: The door is open.
•
PELLET DAMPER: The damper is closed.
•
EXIT: Defect exit for external auger.
•
FUEL: The smoke temperature is too low after more than 2 hours in operation and/or there is not
enough fuel.