MACHINE TRANSPORT/PARKING
To transport/park the machine, proceed as follows.
Turn the brush/pad-holder switch and the vacuum system switch (65 and 66) to “0”.
1.
Lift the squeegee with the lever (19).
2.
Grasp the handlebar (2) and slightly lower it until the rear wheel (7) comes into contact with the
fl
oor (Fig. 4). While holding the
3.
machine in this position, push it to the transport/parking area.
In order not to drag the brush/pad on the
fl
oor and leave wet marks, when
fi
nishing working, remove the brush/pad-holder from
4.
the deck by using the release device (see the procedure in After Using The Machine paragraph), then place it on the support
(43).
Figure 4
S310229A
TANK EMPTYING
An automatic
fl
oat shut-off system (46) turns off the vacuum system when the recovery tank (31) is full.
The vacuum system shutdown, due to the recovery tank
fi
lling, is signalled by an increase in the vacuum system motor noise,
moreover the
fl
oor is not dried.
CAUTION!
If the vacuum system turns off accidentally (for example, when the
fl
oat is activated because of a sudden
machine movement), to resume the operation: turn off the vacuum system by pressing the switch (66), then
open the cover (6) and check that the
fl
oat inside the grid (46) has gone down to the water level. Then close the
cover (6) and turn on the vacuum system by pressing the switch (66).
When the recovery tank (31) is full, empty it according to the following procedure.
Recovery tank emptying
Start the machine by pressing the brush/pad-holder and vacuum system switches (65 and 66).
1.
Lift the squeegee with the lever (19).
2.
Drive the machine to the appointed disposal area.
3.
Insert the positioning pin (24) and lift the brush/pad-holder by activating the transport/parking device (23a).
4.
Empty the recovery tank with the drain hose (16). Then, rinse the tank with clean water.
5.
Solution tank emptying
Perform steps 1 to 4.
6.
Empty the solution tank by using the drain valve (18). Then, rinse the tank with clean water.
7.
AFTER USING THE MACHINE
After working, before leaving the machine:
Remove the brush/pad-holder as follows:
1.
With the brush/pad-holder lifted, turn the brush/pad-holder switch (65) to “I” and, after a few seconds, back to “0”, thus
•
releasing the brush/pad-holder.
Empty the tanks (31 and 32) as shown in the previous paragraph.
2.
Perform the daily maintenance procedures (see the Maintenance chapter).
3.
Store the machine in a clean and dry place, with the brush/pad and the squeegee lifted or removed.
4.