RECOVERY SYSTEM
MAINTENANCE OF RECOVERY TANK FLOAT SWITCH
If the recovery tank
fl
oat switch becomes dirty it can impair the vacuum motor operation. A dirty
fl
oat/vacuum shutoff switch can cause the vacuum motor to not
function at all or to not shut off when the tank is full.
If daily rinsing of the recovery tank does not keep the switch clean, you may need to remove the
fl
oat arm for cleaning. The
fl
oat arm can be removed easily by
grasping it as shown below and twisting it to remove. It is very important that it be reassembled correctly in order to function. See
Figure 3
for the correct orientation
of the switch
fl
oat arm.
FIGURE 3