background image

9

English

08/07/22 Rev:1.0.1

4 KIT AND ACCESSORIES

Check that the product corresponds to what was ordered and that there is no obvious damage
caused by transport, otherwise notify the retailer immediately.
After opening the packaging, check that the material contained in the package is
conforms to the list below:

1) 

 N°1 vacuum unit

2)  

N°1 

fi xing plate for wall mounting of the vacuum unit

3) 

 N°1 gum sleeve for the connection to the piping network   

4) 

 N°4 metal clamps for sleeves fi xing

5) 

 N°1 warranty form  

6) 

 N°1 assembly, use and maintenance manual

7) 

 N°1 dust inlet closing cap

2

1

3

4

6

MANUALE TECNICO

7

5

Summary of Contents for AP1000.50.07

Page 1: ...1 CENTRAL VACUUM UNIT NOVA 1 PLUS ASSEMBLY USE AND MAINTENANCE MANUAL ...

Page 2: ......

Page 3: ...DIMENSIONS 5 3 1 Identification plate 8 3 2 Safety symbols 8 4 KIT AND ACCESSORIES 9 5 PROPER USE OF THE PRODUCT 10 6 INSTALLATION 10 6 1 Instruction for the installation of systems 10 6 2 Positioning 11 6 3 Connection to the piping network 12 6 4 Electrical connection 13 7 START UP AND USE 13 7 1 Thermal switch 14 8 MAINTENANCE AND END OF LIFE 15 8 1 Spare parts 15 8 2 End of life 15 9 SAFETY REQ...

Page 4: ...this manual and to the equipment at any time without obligation to advise third parties 2 WARNINGS Do not use the product for improper uses This product must not be used by children or persons without the appropriate knowledge Only use original spare parts In order to be able to operate the product easily it must be installed leaving a space around it completely free of any obstructions This produ...

Page 5: ...al switch A 9 Maximum air flow m3 h 225 Filtering surface cm2 6700 Filtering material PTFE H11 Dust container capacity l 21 Weight kg 10 5 Measurement A mm 363 Measurement B mm 145 Measurement C mm 555 Measurement D mm 86 Measurement E mm 63 Measurement F mm 305 Measurement G mm 906 Measurement H min mm 100 Measurement I mm 356 Measurement L mm 180 Measurement M mm 20 Noise Level dB A 70 N B Nomin...

Page 6: ...undproof dome Electric power cable Activation signal cable micro lines Thermal switch Main switch Motor Air exhaust blowing outlet Machine body Bucket seal holder Dust container Dust inlet with suction inlet Handle and closure hook Filter cartridge 2 1 3 4 6 7 14 13 12 11 5 9 8 10 ...

Page 7: ...venting Dust entry seal Dust inlet with Handle and closure hook 5 6 4 7 8 9 10 12 11 Motor Lower motor seal Upper motor seal Front Machine body Filter cartridge Filter tightening knob Dust bin Conveyor cone with gasket 14 13 15 16 17 18 20 19 1 2 3 Cover Main switch Printed Circuit Board ...

Page 8: ...GER OF VOLTAGE OR ELECTRICAL CURRENT Danger of serious personal injuries During maintenance operations always disconnect the power supply and make sure that it cannot be restored DANGER OF CUTTING Danger of serious personal injuries During maintenance operations always disconnect the power supply and make sure that it cannot be restored DANGER OF AUTOMATIC STARTING Danger of serious personal injur...

Page 9: ...ely After opening the packaging check that the material contained in the package is conforms to the list below 1 N 1 vacuum unit 2 N 1 fixing plate for wall mounting of the vacuum unit 3 N 1 gum sleeve for the connection to the piping network 4 N 4 metal clamps for sleeves fixing 5 N 1 warranty form 6 N 1 assembly use and maintenance manual 7 N 1 dust inlet closing cap 2 1 3 4 6 MANUALE TECNIC O 7...

Page 10: ...st also comply with the requirements of this manual as well as inform the user of the operation and maintenance of the installed products and report any dangers related to their use It is necessary to leave a free space of adequate size all around the product in order to permit any repair maintenance or inspection operation The product should not be exposed to atmospheric agents and should not be ...

Page 11: ...ided 5 the minimum radius of the curves must be equal to or greater than 0 5 meters 6 sections of pipes that include both positive and negative siphons must be avoided 7 the sections of horizontal pipes must be kept perfectly leveled 8 vertical pipe sections longer than 3 5 meters must always be avoided and at the bases of these the minimum radius of the bends must be equal to or greater than 1 me...

Page 12: ...sported The quantity of curves in the tract where the fuel passes through The length of vertical tracts where the fuel passes through The exhaust pipe air expulsion from the unit maximum length admitted is 5 m single pipe system The exhaust pipe of the air from the unit maximum length admitted in case it returns to the point of fuel sampling is 10 m double pipe system See installation data sheet o...

Page 13: ...O OUT AUX REED MICRO IN TIMER VALVE SENSOR A SENSOR B PNP NPN PNP NPN POT RELAY SWITCHING AC DC FUSE RELAY RELAY L N F0030683 ALARM MICRO OUT AUX REED MICRO IN ER VALVE SENSOR A SENSOR B PNP NPN PNP NPN L N REED MICRO IN SENSOR A SENSOR B PNP NPN PNP NPN L N F0030683 ALARM MICRO OUT AUX ER VALVE Don t use the vacuum unit without filter cartridge Before proceeding to unit start up it is opportune t...

Page 14: ...rol panel see 6 4 In order to avoid irreparable damages to the filter and the central unit the suction of fine powders such as ash cement gypsum flour talcum etc must be avoided without the interposition of an additional and adequate filter available among those in the catalog 7 1 Thermal switch The thermal switch s task is to protect the electrical and electronic parts of the vacuum cleaning unit...

Page 15: ...The checks to be carried out at least every two weeks are clean the filter with compressed air or wash it with low pressure water Empty the dust collecting bucket The filter cartridge should always be correctly fixed A wrong mounting could cause serious damages to the motor and the control panel Do not use the vacuum unit without the filter cartridge It is also advisable to thoroughly clean the fu...

Page 16: ...gen In the 4 weeks after the fuel filling enter only with a CO detector Aerate the storage room for at least 15 minutes before entering and keep the door open during your permanence Ensure an adequate and permanent aeration of the storage room through vent covers openings or fans Wounding risk for moving systems Turn off the boiler at least one hour before the pellet is delivered Proceed to the fi...

Page 17: ...accident abuse misapplication repair alteration or unauthorized disassembly 2 maintenance operation use which is not in accordance with the product instructions or connection to an improper voltage supply or 3 use of consumables and spare parts which are not supplied by the manufacturer or authorized service center Valid warranty claims are generally processed through the point of purchase of the ...

Page 18: ...h Regulation EC 1907 2006 REACH or registration evaluation authorization and restriction of chemical substances Although in the working cycles of raw materials and our products such substances are not used their presence in the size of p p m parts per million cannot be excluded due to micro pol lution of raw materials EC declaration of conformity The Manufacturer declares that its products and equ...

Page 19: ......

Page 20: ...VACUUM UNIT NOVA 1 PLUS F0920247 1 info advanceeasymoving com www advanceeasymoving com ...

Reviews: