SAFETY INSTRUCTIONS

 

 

BEFORE USING THIS EQUIPMENT

 

Read this manual and become familiar with safety markings and instructions.

 

Inspect unit for any sign of external damage. Do not use this equipment if there is physical damage or missing parts.

 

Verify the input AC voltage to the main power supply

 

 

For a system with a digital controller option  – DO NOT USE OR CONNECT a PoE enabled ethernet switch to a 
system. Our digital controller does not support PoE connection and will cause permanent damages to a controller 
unit. 

 

 

INTENDED USE

 

This product is intended for general laboratory use in a wide variety of industrial and scientific applications. 

 

 

RF OUTPUT LOAD & PROPER GROUNDING REQUIRED

 

The RF output connector must be connected to a load before the AC switch is on.

 

AC & RF power must be off before disconnecting the output load or other components.

 

The main power source to the equipment must have an uninterrupted safety ground that has sufficient size to the 
power cord.

 

 

REPAIR & MAINTENANCE

 

All  repair  or  maintenance  work  must  be  performed  by  a  factory  authorized  technician  in  order  to  extend  the 
operating life of this equipment and not to void any outstanding warranty.

 

 

FORCED AIR COOLING

 

This equipment requires forced air cooling.    All air inlets and outlets must be cleared and free of blocking at all 
time.    Insufficient air flow will result in damaged equipment.

 

 

SAFETY SYMBOLS

 

 

This symbol is marked on the equipment when it is necessary for the user to refer to the manual 
for important safety information. This symbol is  indicated in the Table of Contents to assist in 
locating pertinent information.

 

 
 

Dangerous voltages are present. Use extreme care.

 

 

 

The  caution  symbol  denotes  a  potential  hazard.  Attention  must  be  given  to  the  statement  to 
prevent damage, destruction or harm.

 

 

This symbol indicates protective earth terminal.

 

 

 

Summary of Contents for AA-13G-500/1KWP

Page 1: ...1 P a g e Ver 1 1 09 22 Instruction Manual Including Quick Start Guide Advanced Amplifiers Solid State RF Amplifier System AMP2103P LC AA 13G 500 1KWP 0 8 3 2 GHz 1000 Watt Pulse 500W CW 60 dB Min...

Page 2: ...PECIFICATIONS 4 AVAILABLE SPECIAL OPTIONS 4 OPERATING INSTRUCTIONS GENERAL INFORMATION 5 INTRODUCTION 5 INCOMING INSPECTION 5 RF AC CABLE CONNECTION 5 RF TURN ON PROCEDURE 5 RF TURN OFF PROCEDURE 5 DE...

Page 3: ...ecting the output load or other components The main power source to the equipment must have an uninterrupted safety ground that has sufficient size to the power cord REPAIR MAINTENANCE All repair or m...

Page 4: ...nits with optional digital monitor and control for basic units 1 minute at rated Pout 3 Droop 1dB Typ 100usec overshoot droop 1dB Typ 560 sec ENVIRONMENTAL CHARACTERISTICS Parameter Specification Note...

Page 5: ...rface and commands list is in the second part of the manual RF AC CABLE CONNECTION RF Input and Output connectors are outlined in the specifications table Use the standard AC cable that was supplied b...

Page 6: ...or replacement of defective goods F O B factory of which Seller is modified in writing by Buyer within three 3 years following delivery thereof to Buyer and in no event will Seller be liable for incid...

Page 7: ...Control LCD Panel 3 FAULT LED System Fault LED Turn ON an LED when Over Temp Ext Shutdown 4 POWER LED Turn On a LED when Power Supply On 5 GATE CONTROL CW mode a TTL high of 3 3 5 0vdc is applied to a...

Page 8: ...P7 N C P3 RX P8 N C P4 RX P9 N C P5 GND RS 422 5 DEBUG System Controller Debugging Female Connector Port access required factory authorization 6 USB USB Communication Connector Type A Female 7 ETHERN...

Page 9: ...9 P a g e Ver 1 1 09 22 SYSTEM OUTLINE VIEW...

Reviews: