background image

 

4  | 

P a g e

 - Ver. 1.1 - 09-22

 

SPECIFICATIONS

 

ELECTRICAL SPECIFICATIONS

: 50Ω, 25°C

 

Parameter

 

Specification

 

Notes

 

Operating Frequency Range 

0.8 - 3.2 GHz 

 

Power Output @ Pulse 

1000 Watt Typ 

Peak Pulse 

Pulse Characteristics 

Width 

Duty 

PRF 

Droop/O-shoot 

RF Rise/Fall 

up to 560µS 

up to 10% 

up to 10kHz 

1 dB Typ

3

 

50nS Typ 

Power Output CW 

500 Watt Min 

CW 

Power Gain 

60 dB Min 

0dBm or less for rated Pout 

Gain Adjustment Range 

20 dB Min 

Local or remote 

Power Gain Flatness 

4.0 dB p-p Max 

Constant input power 

Input Return Loss 

-10 dB Max 

 

Harmonics 

<-20 dBc Typ 

At rated output power 

Spurious 

-60 dBc Max 

Non-harmonics 

Output Power On/Off Ratio 

-80 dB Typ 

TTL Gate Control 

Operating Voltage 

120/208 VAC, 3-Phase 

Option: 220 VAC Nom, 1-Phase 

Power Consumption CW / Pulse 

5500 / 2500 Watts Max 

At rated Pout 

Input Power Protection 

+10 dBm Max

1

 

 

Load VSWR Protection 

4 : 1: Max

2

 

Foldback @ preset limit 

Sample Port Coupling (optional) 

-60 dB 

N-Female 

1 Units with optional digital monitor and control, for basic units <10 Sec without damage

 

2 Units with optional digital monitor and control, for basic units <1 minute at rated Pout

 

3 Droop <1dB Typ @100usec, overshoot & droop >1dB Typ @ 560µsec

 

ENVIRONMENTAL CHARACTERISTICS

 

Parameter

 

Specification

 

Notes

 

Operating Ambient Temperature

 

0 to +50 °C

 

 

Storage Temperature

 

-40 to +85 °C

 

 

Relative Humidity

 

up to 95 %

 

Non-condensing

 

Altitude

 

3000 meters

 

 

Shock & Vibration

 

Normal transport

4

 

 

4 MIL Spec available for quotation

 

MECHANICAL SPECIFICATIONS

 

Parameter

 

Specification

 

Notes

 

Dimensions W x H x D

 

482 x 398 x 750 mm

 

9U, excluding handles

 

Weight

 

60 Kg. Typ

 

 

RF Connectors Input/Output/Sample

 

N-Female / 716 DIN / N-Female

 

Front or rear panel

 

Gate Control

 

BNC Female

 

Front panel

 

Interface Connector

 

9-Pin D-Sub

 

Rear panel

 

AC Power

 

IEC 60320-C14

 

Or equivalent

 

Cooling: Built in Quiet-Cool

 

Close circuit Air-liquid cooling

 

 

STANDARD:

 Digital Monitor & Control (DMC)

 

FWD, REV, VSWR, GAIN, ALC, V & I, TEMP,

 

Optional Safety Interlock (INT)

 

Ethernet RJ-45 TCP/IP, RS422/485, USB

 

GPIB Interface

 

Open=STBY/Short=RFON

 

 

IEEE rear panel

 

BNC-F rear panel

 

AVAILABLE SPECIAL OPTIONS

 

Parameter

 

Specification

 

Notes

 

Option FRS: Forward RF Sample

 

-60dB, Type N-Female

 

Front or rear panel

 

Option RRS: Reflected RF Sample

 

-50dB, Type N-Female

 

Front or rear panel

 

 

 

Summary of Contents for AA-13G-500/1KWP

Page 1: ...1 P a g e Ver 1 1 09 22 Instruction Manual Including Quick Start Guide Advanced Amplifiers Solid State RF Amplifier System AMP2103P LC AA 13G 500 1KWP 0 8 3 2 GHz 1000 Watt Pulse 500W CW 60 dB Min...

Page 2: ...PECIFICATIONS 4 AVAILABLE SPECIAL OPTIONS 4 OPERATING INSTRUCTIONS GENERAL INFORMATION 5 INTRODUCTION 5 INCOMING INSPECTION 5 RF AC CABLE CONNECTION 5 RF TURN ON PROCEDURE 5 RF TURN OFF PROCEDURE 5 DE...

Page 3: ...ecting the output load or other components The main power source to the equipment must have an uninterrupted safety ground that has sufficient size to the power cord REPAIR MAINTENANCE All repair or m...

Page 4: ...nits with optional digital monitor and control for basic units 1 minute at rated Pout 3 Droop 1dB Typ 100usec overshoot droop 1dB Typ 560 sec ENVIRONMENTAL CHARACTERISTICS Parameter Specification Note...

Page 5: ...rface and commands list is in the second part of the manual RF AC CABLE CONNECTION RF Input and Output connectors are outlined in the specifications table Use the standard AC cable that was supplied b...

Page 6: ...or replacement of defective goods F O B factory of which Seller is modified in writing by Buyer within three 3 years following delivery thereof to Buyer and in no event will Seller be liable for incid...

Page 7: ...Control LCD Panel 3 FAULT LED System Fault LED Turn ON an LED when Over Temp Ext Shutdown 4 POWER LED Turn On a LED when Power Supply On 5 GATE CONTROL CW mode a TTL high of 3 3 5 0vdc is applied to a...

Page 8: ...P7 N C P3 RX P8 N C P4 RX P9 N C P5 GND RS 422 5 DEBUG System Controller Debugging Female Connector Port access required factory authorization 6 USB USB Communication Connector Type A Female 7 ETHERN...

Page 9: ...9 P a g e Ver 1 1 09 22 SYSTEM OUTLINE VIEW...