Offset
Field
Size Value
Description
40
dwFeatures
4
-
ACR3901U-S1 supports the following
features:
•
Automatic ICC clock frequency change
according to parameters
•
Automatic baud rate change according
to frequency and FI,DI parameters
•
TPDU level change with ACR3901U-
S1
44
dwMaxCCIDMessageLength
4
-
Maximum message length accepted by
ACR3901U-S1 is 271 bytes
48
bClassGetResponse
1
-
Insignificant for TPDU level exchanges
49
bClassEnvelope
1
-
Insignificant for TPDU level exchanges
50
wLCDLayout
2
-
No LCD
52
bPINSupport
1
-
With PIN Verification
53
bMaxCCIDBusySlots
1
-
Only 1 slot can be simultaneously busy