background image

Z-Wave ZDW103 Series 200, Release 2.2 Instructions
P/D 020708

HomePro

by ADVANCED CONTROL TECHNOLOGIES, INC.

0760-01

4

You can use a ZTH100 to send Configuration commands. (Refer to the Setup Menu, Configuration section)

Set Ignore Start Level Bit When Transmitting Dim Commands

The ZDW103 can send Dim commands to Z-Wave enabled dimmers. The Dim command has a start level
embedded in it.  A dimmer receiving this command will start dimming from that start level if this bit is set to 0.
If the bit is set to 1, the dimmer will ignore the start level and instead start dimming from its current level.

•   Parameter No: 1
•   Length: 1 Byte
•   Valid Values  = 0 or 1 (default 1)

Night Light

The LED on the ZDW103 will by default, turn ON when the load attached is turned ON. To make the LED turn
ON when the load attached is turned OFF instead, set parameter 3 to a value of 1.

•   Parameter No: 3
•   Length: 1 Byte
•   Valid Values = 0 or 1 (default 0)

Invert Switch

To change the top of the switch to OFF and the bottom of the switch to ON, set parameter 4 to 1.

•   Parameter No: 4
•   Length: 1 Byte
•   Valid Values = 0 or 1 (default 0)

Ignore Start Level When Receiving Dim Commands

The ZDW103 can be set to ignore the start level that is part of the dim command, regardless

 

of whether the

command itself is telling the dimmer to ignore the start level or not ignore the start level embedded in the command
(see Parameter 1). Setting parameter 5 to a value of 0 will cause the ZDW103 to stop ignoring the start level and
cause it to dim based on the command sent.

•   Parameter No: 5
•   Length: 1 Byte
•   Valid Values = 0 or 1 (default 1)

Adjusting Dim Rate

There are 3 sets of  parameters that can adjust the dimming rate of the ZDW103.

1.   One set to control how fast the dim rate is when the dimmer receives a Z-Wave command

 excluding ALL ON or ALL OFF command (Parameter 7 and 8).

2.    One set to control how fast the dim rate is when the dimmer is locally controlled (Parameter 9 and 10).
3.     One set to control how fast the dim rate is when the dimmer receives an ALL ON or ALL OFF command

 (Parameter 11 and 12).

These values can be changed instantly to allow various scenes and effects.
The first of these parameters is the “dim step” (dim rate) parameter. It can be set to a value of 1 to 99. This value
indicates how many levels the dimmer will change when the timer (discussed below) expires.
The second parameter is the timing (how fast the dim rate) parameter. It can be set  to a value of  1 to 255.
This value indicates in 10 millisecond resolution, how often the dim level will change. For example,  if you set
this parameter to 1, then every 10mS the dim level will change. If you set it to 255, then every 2.55 seconds the
dim level will change.
With the combination of the two parameters that can control the dim rate, the dimmer can be adjusted to dim
from maximum to minimum or minimum to maximum at various speeds between 10 millisecond and 252.45
seconds (over 4.25 minutes).

•   Parameter 7-12
•   Length: 1 Byte
•    Valid Values: (See next)

Summary of Contents for HomePro ZDW103

Page 1: ...ons in the United States or the Canadian ElectricalCodeandlocalregulationsinCanada Itisrecommendedthataqualifiedelectricianperformthisinstallation Therearenofieldrepairableassembliesonthisunit Ifserviceisneeded theunitmustbereturnedwherepurchased CAUTION To reduce the risk of overheating and possible damage to other equipment do not install to control a receptacle a motor operated appliance a fluo...

Page 2: ...work Refer to controller instructions STEP 2 The ZDW103 must be in its permanently installed location Tap either the top or bottom of the ZDW103 switch once STEP 3 You should see an indication on your Controller that the DEVICE WAS INCLUDED in the network NOTE If you have trouble adding the ZDW103 to a group it may be that the Home ID and Node ID were not cleared from it after testing You must fir...

Page 3: ...on You can turn on and off and even dim other Z Wave devices once they are associated in either of 2 groupswithZDW103 A NOTE ABOUT DIMMERS IN A GROUP If you combine Z Wave enabled dimmers and other types of Z Wave devices in a group place a Z Wave enabled dimmer into the empty group first to ensure that the dimming operates correctly Each group is turned on off or dimmed by tapping or holding the ...

Page 4: ...ameter1 Settingparameter5toavalueof0willcausetheZDW103tostopignoringthestartleveland cause it to dim based on the command sent Parameter No 5 Length 1 Byte Valid Values 0 or 1 default 1 Adjusting Dim Rate There are 3 sets of parameters that can adjust the dimming rate of the ZDW103 1 One set to control how fast the dim rate is when the dimmer receives a Z Wave command excluding ALL ON or ALL OFF c...

Page 5: ...he entire time it is transmitting set to 1 or to flicker for only 1 second when it begins transmitting set to 2 By default the ZDW103 is set to flicker for only 1 second Parameter 19 Length 1 Byte Valid Values 0 1 2 default 2 Each Configuration Parameter can be set to its default setting by setting the default bit in the Configuration Set command See your controller s instructions on how to do thi...

Page 6: ...e FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interfer ence received including interference that may cause undesired operation FCCNOTICE Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are design...