PK-88 OPERATING MANUAL
COMMAND SUMMARY
5 - 32
PK-88 - 107
DISPLAY
[class]
Mnemonic:
DISP
Immediate Command
Parameters:
class
Optional parameter identifier, one of the following:
(A)sync
display asynchronous port parameters
(C)haracter
display special characters
(I)d
display ID parameters
(L)ink
display link parameters
(M)onitor
display monitor parameters
(T)iming
display timing parameters
(Z)
display the entire command/parameter list
DISPLAY is an immediate command.
When
DISPLAY
is typed without a parameter, the PK-88 responds with:
cmd:
DISPLAY A,C,I,L,M,T,Z
cmd:
You can display subgroups of related system parameters by specifying the optional class parame-
ter:
cmd:
disp a
8BITCONV OFF
ACRDISP 80
AFILTER OFF
ALFDISP OFF
AWLEN 7
CASEDISP 0
ECHO ON
ESCAPE OFF
FLOW ON
ILFPACK OFF
NUCR OFF
NULF OFF
NULLS 0
PARITY 3
TBAUD 1200
TRFLOW OFF
TXFLOW OFF
XFLOW ON
cmd:
Individual system parameter values can be displayed by entering the parameter name without op-
tions.
cmd:
mycall
cmd:
frack
cmd:
dwait
MYCALL WX1AAA
FRACK 3
DWAIT 16