1316-900 Revision AA
10kW Precision Calorimeter
12
Instrument Connections
WARNING:
High voltage and current are present on the system. Install proper
safety equipment (e.g., fuses, breakers, etc.) as necessary between the AC Power
Source and Voltage/Current RF Adapter. Failure to install adequate safety equipment
may result in death or bodily injury, or equipment damage.
1.
Connect the Voltage/Current RF Adapter through an appropriately sized fuse or breaker
to the AC Power Source. See
Figure 1: Voltage/Current RF Adapter connections to the AC Power Source.
WARNING:
Dangerous voltage, current, and RF power may be present on the
system. Users should install interlock devices as appropriate for safe operation.
2.
Connect interlocks (user-supplied) to the Calorimeter and system as necessary.
3.
Connect the Calorimeter and Power Analyzer ethernet ports to the network.
4.
Connect the AC Power Source to the network using the ethernet port or the RS-232
serial connection. Ethernet is preferred.
5.
Connect the thermocouple from the Calorimeter to the 12 kW Chiller as shown in