When an Anybus module is inserted into the unit, guide the module towards the left during
insertion.
4. Secure each module with the two TORX
®
T8 screws provided with the module.
If an Anybus module must be removed from the unit, loosen the TORX T8 mounting screws 3 turns,
and pry out the module with a small flat-bladed screwdriver, as shown in the following figure.
Figure 6. Anybus module removal
WRITE AND READ ASSEMBLIES
Assemblies enable the sending or receiving of data via a single connection. This can be input and
output data, status and control information, or diagnosis information. The terms input and output
assemblies are defined from the perspective of the network. The input assemblies produce (write) data
on the bus; the output assemblies consume (read) data from the bus. With the aid of write and read
assemblies, cyclical IO data are transmitted.
The Thyro-PX Ethernet IP module contains several sets of assemblies. The user can select the
corresponding assemblies depending on how many flexible links are needed.
The following write and read assembly combinations are possible:
• Write assembly 101, with read assemblies:
◦ 111
◦ 112
◦ 113
• Write assembly 102, with read assemblies:
◦ 112
◦ 113
Advanced Energy
®
Thyro-PX
™
Anybus
®
Ethernet IP
57010163-00A
Thyro-PX
™
Anybus
®
Ethernet IP
8