1.0 IMPORTANT SAFETY INSTRUCTIONS

2.0 Placement & Mounting Requirements

The LiveLED 100, is designed to operate in an indoor or outdoor environment. The proper voltage 
required at the site is 110 - 240 VAC, 60/50 Hz. The unit draws 1 Amp at 120 volts.  The LiveLED 
100 is yoke mounted and is designed for operation in any orientation allowed by the yoke. The 
LiveLED 100 must be adequately ventilated.  Recommended operating temperatures are from -30 
degrees F (-35 degrees C) to 140 degrees F (60 degrees C). The illuminator should be placed with 
6-8” inches clearance on the sides and 12” inches of back clearance if unit is placed in front of an-
other unit. When more than one LiveLED is installed in the same location, provide each unit with the 
same minimum clearances as noted above. Proper ventilation is absolutely necessary to maintain 
LED life.

SAVE THESE INSTRUCTIONS.

• 

WARNING: RISK OF INJURY.

• 

 

WARNING: THE HEAT SYNC COMPONENT OF THIS UNIT MAY BECOME HOT DURING 

• 

        OPERATION. TAKE CAUTION WHEN HANDLING UNIT DURING OPERATION.
  

WARNING: RISK OF ELECTRIC SHOCK.

• 

 

CAUTION: CONNECT ONLY TO A CIRCUIT PROTECTED BY A CLASS A GROUND FAULT 

• 

CIRCUIT INTERRUPTER 

DO NOT BURY POWER CORD

• 

READ & FOLLOW ALL INSTRUCTIONS

3.0 General Operating Instructions

With the unit properly installed, plug the illuminator power inlet cable into a suitable AC power 
source. The LED modules will immediately light. The DMX color control system will cycle and then 
stop on specific colors relative to whatever control settings the unit is currently set to.  Unless oth-
erwise specified, units are shipped with color controls not preset. Color control setup is required to 
achieve desired colors and effects. All color and effects control is activated using the 3 rotary knobs 
on the unit (see control panel picture).  The unit may operated as a stand alone single unit, in master/
slave configuration with other units or remotely using USITT DMX 512 control protocol generated by 
an external unit. Consult the instructions for the DMX controller or other signal processor that will be 
used for programming instructions. The DMX signal can be delivered through either of the XLR con-
nectors located on the bottom left of the illuminator (see control panel picture). The remaining con-
nector can be used as an output signal  (in the case of a daisy chain) or left un-used (terminated).

Summary of Contents for ALS-LLED-100

Page 1: ...ALS LLED 100 Model Number Installation INSTRUCTIONS LiveLED 100 ...

Page 2: ...s been engineered and designed to be simple to operate energy efficient and reliable The LiveLED 100 is designed for architectural entertainment and other applications where white and color light washing is required The LiveLED 100 is a digital full spectrum capable source comprised of 39 6 watts of Blue LEDs 39 6 watts of Green LEDs and 22 watts of Red LEDs The LiveLED 100 features an integrated ...

Page 3: ...G UNIT DURING OPERATION WARNING RISK OF ELECTRIC SHOCK CAUTION Connect only to a circuit protected by a class a ground fault circuit interrupter DO NOT BURY POWER CORD READ FOLLOW ALL INSTRUCTIONS 3 0 General Operating Instructions With the unit properly installed plug the illuminator power inlet cable into a suitable AC power source The LED modules will immediately light The DMX color control sys...

Page 4: ...SLAVE OPERATION The master slave control allows multiple units to operate in synchronization without an external con troller Using 3 pin XLR cables link the units together to the XLR cables on the rear of each LiveLED Either connector may be used as either the in or out Choose a unit to be the Master Set the rotary knobs of the Master to the desired preset program see preset program table below Se...

Page 5: ...te 0 5 second strobe 681 Cool White 0 25 second strobe 682 Cool White 0 1 second strobe COLOR STROBE flash on off pause for time indicated 640 8 Color snap change w 10 second pause 641 8 Color snap change w 5 second pause 642 8 Color snap change w 2 second pause 643 8 Color snap change w 1 second pause 644 8 Color snap change w 0 5 second pause 645 8 Color snap change w 0 25 second pause COLOR SNA...

Page 6: ... Setting the Base DMX Address As with all products that are DMX controlled the LiveLED 100 requires that DMX channels be set to specific addresses in order that the unit will respond to a control unit Using the adjustment knobs set the desired DMX address on any address from 001 512 The LiveLED 100 uses 5 DMX channels on a control board CHANNEL 1 Red CHANNEL 2 Green CHANNEL 3 Blue CHANNEL 4 Prepro...

Page 7: ...7 4 RGB 20 Crossfade 198 208 4 RGB 15 Crossfade 209 219 4 RGB 10 Crossfade 220 230 4 RGB 05 Crossfade 231 241 4 RGB 01 Crossfade 242 252 5 No Action 0 9 5 RMY 30 Crossfade 10 19 5 RMY 20 Crossfade 20 29 5 RMY 15 Crossfade 30 39 5 RMY 10 Crossfade 40 49 5 RMY 05 Crossfade 50 59 5 RMY 01 Crossfade 60 69 Channel Color Crossfades DMX Value Min DMX Value Max 5 8 Color 10 Snap 70 79 5 8 Color 05 Snap 80...

Page 8: ...l White Strobe 0 25 230 239 5 Cool White Strobe 0 1 240 249 6 0 Quick Settings of Preset Colors Effects Cont The DMX program allows a DMX controller to have complete control of color and effects For custom cues the programmer may use channels 1 through 5 If DMX controlled pre programmed sequences is required the programmer should use a cue loop to send regular updates of the DMX values to the othe...

Page 9: ...or Address issues Check for proper DMX address 9 0 Maintenance of Luminaire 8 0 Troubleshooting Prior to any maintenance or service of the unit always disconnect power cord and allow unit to cool for at least five 5 minutes Periodic Cleaning Clean the LiveLED at least once every 6 months Dust exterior with a soft cloth Make certain that lenses are free of obstructions and debris Fuse Replacement I...

Page 10: ...ponents with any other manufacturer will void the entire warranty WARRANTY SERVICE CLAIMS Nexxus Lighting must issue a Return Material Authorization RMA number for all requests for warranty review To expedite service please contact Nexxus Lighting Customer Representative 407 857 9900 If you are unsure whether a situation exists that is covered by this warranty please contact Nexxus Lighting Custom...

Reviews: