SMD23E2 and SMD24E2 User’s Manual
ADVANCED MICRO CONTROLS INC.
78
Command Blocks (continued)
Preset Position
Table R6.13 Preset Position Command Block
Unused words are ignored by the SMD23E2 and SMD24E2 and can be any value, including parameter values
from the previous command.
Presetting the position resets the
Position_Invalid
and
Move_Complete
status bits in the Network Input Data.
Reset Errors
Table R6.14 Reset Errors Command Block
Unused words are ignored by the SMD23E2 and SMD24E2 and can be any value, including parameter values
from the previous command.
Resetting errors will also reset the
Move_Complete
status bit in the Network Input Data. Resetting errors will
not reset the
Position_Invalid
or
Configuration_Error
bits.
PROFINET
Word
Function
Units
Range
0
16#0200
1
See pg. 71
2
Position Preset Value: Upper
Word
Steps
Combined value between
–8,388,608 and +8,388,607
3
Position Preset Value: Lower
Word
4
Unused
See Note Below
5
Unused
See Note Below
6
Unused
See Note Below
7
Unused
See Note Below
8
Unused
See Note Below
9
Unused
See Note Below
PROFINET
Word
Function
Units
Range
0
16#0400
1
See pg. 71
Set bit 10 to clear
motor faults
2
Unused
See Note Below
3
Unused
See Note Below
4
Unused
See Note Below
5
Unused
See Note Below
6
Unused
See Note Below
7
Unused
See Note Below
8
Unused
See Note Below
9
Unused
See Note Below