INSTALLATION INSTRUCTIONS

 

1.

 

Remove the two wall brackets from the accessory box, and slide them into the slot on the bottom of the sign, 
and tighten all screws for all four brackets at the desired mounting locations. Screw brackets into the wall 
using mounting hardware appropriate for the installation surface chosen. 

2.

 

Remove the water-resistant network cable housing (required for outdoor installations) from the accessory 
box, and attach it to a network cable (outdoor-rated CAT 5 or better), not included, threading the network 
plug left to right as pictured below. The housing includes six pieces. Use the side openings on pieces B, C, and 
D to fit them around the network cable. The network plug will snap into place at the end of piece F as shown. 
Once fitting all pieces together, piece A will screw onto the threads of piece F. 

 

3.

 

Plug in the included 7-foot AC power cord into an appropriate weatherproof GCFI receptacle. 

4.

 

Connect the network cable housing (assembled in step 2) to the network coupler on the side of the IPSIGN-O 
by inserting connector and twisting clockwise to lock and seal the interface. Connect the other end of the 
network cable to a properly installed surge protector, then to a Power over Ethernet (PoE) network switch or 
PoE injector on a network with a DHCP server. The AND support site lists some equipment options:  

www.anetdsupport.com/peripherals

. 

5.

 

If properly installed, the unit should boot and show the time within 30 seconds. See

 Boot Sequence

 on next 

page for details. 

6.

 

Consult the IPClockWise User Manual (see 

www.anetdsupport.com/documents

or third-party software guide 

for further instructions on sending text to the device. 

 
 