USER’S MANUAL 

525VA/625VA 

IMPORTANT SAFETY INSTRUCTIONS

 

SAVE THESE INSTRUCTIONS 

This manual contains important safety instructions. Please follow all instructions carefully during installation. 
Read this manual thoroughly before attempting to unpack, install or operate. 

CAUTION

To prevent the risk of fire or electric shock, install in a temperature and humidity controlled 

indoor area, free of conductive contaminants.

 

CAUTION

Risk of electric shock, do not remove the cover. No user serviceable parts. Refer servicing 

to qualified service personnel. 

 

CAUTION-

 

Risk of electric shock, hazardous live parts inside this UPS can be energized from the 

battery supply even when the input AC power is disconnected.

 

CAUTION-

 

Risk of electric shock, Battery Circuit is not isolated from AC input, hazardous voltage may 

exist between battery terminals and ground. Test before touching.

 

NOTICE-  

The UPS is designed to be for use with computer loads only. 

CAUTION-

 This UPS meets Category C2. If used in living area it can cause interference with radio 

equipment. Then you need to make additional provisions.

SETUP 

1 Inspection 

Inspect the UPS upon receipt. Notify the carrier 
and dealer if there is damage. The package is 
recyclable; save it for reuse or dispose of it 
properly. 
 

2 Placement 

 
 

3  Check the Site Wiring 

Fault Indicator

(115V only)

 

Caution:

 If the site wiring fault indicator lights, 

get a qualified electrician to correct the building 
wiring. 

 

4  Connect the loads

 

First, connect the UPS with the AC Mains, then 
plug the loads into the output connectors on the 
rear of the UPS. To use the UPS as a master 
“On/Off” switch, make sure that all of the loads 
are switch “On”. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Caution:

 Do not connect a laser printer to the 

outlets. These UPS outlets provide battery 
power and surge protection to the equipment 
when utility voltage is outside acceptable limits.

 

5  Connect telephone / 

Network Surge 
protection 

Connect a single line telephone or a 10 base-T / 
100 base-T network cable into the RJ-45 / RJ-11 
telephone / network surge protection “IN” jack on 
the back of the UPS. Connect from the “OUT” 
jack with telephone cable (supplied) or network 
cabling (not supplied) to a fax modem or network 
port. 
 

6 Connect 

Computer 

Interface Port

(Optional)

 

Connect the supplied interface cable to the 9-pin 
computer interface port on the back of the UPS. 
Connect to the computer. See software 
document for installation instruction. 
 

7 Operation 

Test

 

1. Connect the UPS to the wall receptacle. 
2. Push on the Main Switch to check the Green 

Line (

) LED is on. 

3. 

Connect your computer equipment with 
sockets of the UPS and pull off the input power 
cable of the UPS from the wall receptacle to 

check if the Line (

) LED is flashing every 3 

seconds. Meanwhile, please check if alarm 
buzzer is beeping. 

4. Try the field working condition by running some 

application programs on your computer and 
repeating step. 

5. Check if the UPS is initiated properly to 

support continuous operation. 

6.

 

IMPORTANT NOTICE:

 Plug the UPS 

into the wall outlet to charge the UPS for over 
8 hours before using the UPS.

 

7. 

STORAGE:

 

Store at -15 to +30 

°

C (+5 to +86 

°

F), charge 

the UPS battery every six months.   

Store at +30 to +45 

°

C (+86 to +113 

°

F), 

charge the UPS battery every three months.

192321932012001 