Epoch-M1C RF Repeater
User Manual V1.1
Advanced RF Technologies, Inc. Proprietary Document
Page 36 of 38
Appendix B: Button Operation
Normal Operation
Power Off
Initializing....
POWER
VFD
ALARM
Normal Operation
6 sec
16 sec
Booting Time
Power On
(off)
(off)
POWER
VFD
ALARM
(Green)
(Red)
The VFD display
will disappear 30
minutes after VFD
button is pressed.
Display Cycle*
POWER
VFD
ALARM
(Green)
(off)
POWER
VFD
ALARM
(Green)
(off)
DL: IN GAIN OUT
-102 80.0 -10
If there is no modem
hardware, the display
will be blank. If a
modem exists, but is
not connected, the
display will read
‘
DIS
’
.
UL: IN GAIN OUT
-102 77.0 -10
Downlink
Uplink
4 sec
BAND MODEM
B + B
’
CON
4 sec
STATUS
INSTALLED
Band & Channel
Install Status
4 sec
If the repeater is
not installed, the
display will read
‘
STATUS
NOT INSTALLED
’
POWER
VFD
ALARM
(Green)
(off)
POWER
VFD
ALARM
(Green)
(off)
POWER
VFD
ALARM
(Green)
(off)
POWER
VFD
ALARM
(Green)
(off)
4 sec
Display Cycle
If the VFD button
is pressed, the
display will come
up again.