12
Safety Switches
To protect the user and the equipment all safety features relevant to the safe
operation of the unit are controlled by microswitches. As soon as one of these
switches is activated or released, the unit shuts off as in accordance with the
set-up in the electronic control system.
The following features are controlled by safety switches:
■ Facial filters, (4) for installation, breakage or other damage
- the unit shuts off
- after cooling time starts. The main fan runs for about
3minutes until after cooling time has expired.
Error Code E02 is shown in the display.
■ Sunbed acrylic, for installation and proper fit
- the unit shuts off.
- after cooling time starts. The main fan runs for about 3
minutes until after cooling time has expired.
- Error code E03 is shown in the display.
■ Main fan per wind-flag switch for installation and functioning
- the unit shuts off.
- after cooling time starts. The main fan runs for about 3
minutes until after cooling time has expired.
Error code E01 is shown in the display.
■ Control Panel/Display, for installation and correct communication with
main PCB.
- The unit shuts off
Error code E08 is shown in the display.
In all cases an error code is shown in the display to indicate the defect. For
further information on these error messages, please see the chapter
Error Codes
NOTICE:
After the defect has been remedied, the error code switches from the initial letter
“E” to the letter “H” accompanied by the same number.
For instance, from E03 to H03.
These error messages must be acknowledged in order to delete the message
and to re-start the unit.
Ackowledging error codes.
After the cause for the error has been removed, the error must be
acknowledged/confirmed in order to be deleted..
To acknowledge the error, push the “+” button.
- The error message is deleted