33
Connect SunFresh system (optional)
The hose feeding the SunFresh nozzle is blue (1).
The discharge hose, leading superfluous water back to the container (2)
is green.
- The connection hoses for the SunFresh system are
connected with the SunFresh container before the container
is put into its designated position on assembly plate.
Put the connection plug (supply cable (3) of the purification system
which is built into the SunFresh container into the connection socket on
the main control board.
Installation of electric ballast tray
Push the electric ballast tray under the sunbed bench. Take care that
connected terminals remain connected and that cables do not get
pinched or damaged.
Layout the cables in a safe and neat way.
Installation of backlighting lamp in the sunbed front
The backlighting lamp is fixed onto two holding brackets. The holding
brackets are fixed with two thumb screws to the sunbed bench.
Take the lamp and adjust the holding brackets to match with the
threaded holes.
Fasten lamps with two thumb screws.
Reconnect power supply for the backlighting lamps.