45
Survey Operator Menue – Set-ups
Operator
menu
Value Description
Display
OEM set-up Optional set-ups
01
Total operating hours equipment
01_>xxxxx
–
No re-set function
02
Operating hours – low-pressure lamps
02_>xxxxx
–
Re-set with button
combination
3x Cooling sunbed,
1x SunHaze, 1x AC
03
When max. operating hours f. low-
pressure lamps have been reached, there
is a blinking point in the lower right corner
of the display. Deactivate this function by
entering “000”.
03xxx
000
04
Operating hours – HID lamps
04_>xxxxx
–
Re-set with button
combination
3x Facials,
1x SunHaze, 1x AC
05
When max. operating hours f. high-
pressure lamps have been reached, there
is a blinking point in the lower right corner
of the display. Deactivate this function by
entering “000”
05xxx
000
06
00-30 External control device/token box(00) or
internal control (01-30)
06_00
00
07
00-02 AC unit always OFF (00), AC unit ON at
start then optional ON/OFF (01); AC unit
OFF at start then optional ON/OFF (02)
07_01
01
08
00-01 Facials optional OFF (00) or Facials
always ON (01).
08_00
00
09
00-01 Button “STOP” with intermediate function
(00) or button “STOP” never with
intermediate function (01), Stop button
deactivated (02)
09_01
02
10
00-01 Cleaning function activated (00) or
Cleaning function deactivated (01)
10_00
01
After after-cooling time
has expired, the display
shows “Clean”; push
“Start” button to delete the
message after cleaning
the unit.
11
00-50 Temperature set-up for heat-recycling
system
11_25
20
12
00-01 Backlights always ON (00) or Backlights
always OFF (01)
12_00
00
Push the button
combination
“SunFresh” and “–”= OFF
“SunFresh” and “+”= ON.
13
00-08 Start level add. Fan shoulder tanner
13_08
08
ICON – not assigned
14
00-08 Start level fans sunbed
14_08
08
15
00-08 Start level fan top canopy
15_08
08
16
00-03 Delayed switch-off for facials in min.
16_00
00