3.5
Attach the Valve Mount
3.5.1
Verify O-Rings
Check that the O-rings are in place on the Valve
Mount.
3.5.2
Install Valve Mount Screws
Locate the two valve mount screws that were set
aside. Apply Loctite 242 to the tips and attach to
the jet body.
To reinstall the melter using the same cable, skip to Step 3.7.
To install a new melter cable (Advanjet P/N 06-1042-00), continue to Step 3.6.
3A6328A
Advanjet HM-2600 Hotmelt Jet Maintenance and Repair