4
Mounting position on the vehicle
6
Mechanical and electrical mounting
Electrical connection points on the vehicle
The electrical connection point suitable for the DLT-U1100 depends on the respective
vehicle type.
• Make sure to observe the technical/electrical information of the vehicle manufacturer.
• Keep in mind that certain electrical connection points are not suitable for the
DLT-U1100, e.g. for vehicles with braking energy reclamation.
• Position the DLT-U1100 as closely as possible to the connection point and
connect it there.
• Make sure that the connection point exhibits a stable potential level.
• Do not connect the DLT-U1100 directly to the circuit of high power consumption
devices (e.g. converters for forklift drives); this may result in sudden restarts,
malfunctions or damage to the device.
• With some vehicles, the chassis represents DC+. The DLT-U1100 chassis is then also
DC+. If peripheral devices now supply DC-, e.g. via a plug connector through a serial
interface to the shield connection of the DLT-U1100, a short circuit is inevitable and
malfunctions/total failures are unavoidable.
• It must be ensured with these vehicles that the UPS case does not have any electrical
connection to the vehicle body.
5
Electrical connection data
7
Contact
Advantech-DLoG
service@dlog.com
Industriestraße
15
www.advantech-dlog.com
D-82110 Germering
Telefon: (+49) 89 / 41 11 91 - 999
Quickstart Guide DLT-U1100 V1.00 DAN 885196E 01/30/2014
Copyright 2014 by DLoG GmbH, Industriestraße 15, D-82110 Germering
All rights reserved. Information in this document is subject to change without prior notice.
DLT-U1100 dimensions (in mm)
Mounting steps
• Mount the DLT-U1100
1
on the vehicle via the two mounting brackets
and four M3.5x6 mm threaded screws.
• Connect the connection cable
2
to the electrical connection point of the vehicle.
• Connect with the DLT-U1100 (input) as shown in position
6
.
• Connect connection cable
3
to the industrial PC.
• For this purpose, plug the Phoenix contact plug
4
into the UPS connection of the
industrial PC and screw tight.
• Connect and fasten the ground cable to the ground pin of the industrial PC.
• Connect with the UPS (output) as shown in position
7
.
• Fasten all cables securely.
1
2
3
4
5
6
7
Mounting brackets
with 2 drill holes
for M3.5x6 mm
threaded screws
Suitable mounting position
• Take the permissible working temperature range of the DLT-U1100 into account
(heat development of the vehicle, e.g. near the engine).
• The UPS DLT-U1100 heats up during the charging process; for this reason, make sure
to provide for adequate ventilation. Do not cover the UPS.
• Check the available cable length. Both the electronic connection point of the vehicle
and the industrial PC must be easily reached.
• Install the cables according to the regulations. Cables must not interfere with the ongoing
operation or present a hazard to persons.
• Screw the cables sufficiently tight but make sure not to pinch them. Otherwise, the cable
may break or the cable insulation may be damaged.
• Observe the specifications of the vehicle manufacturer for the attachment of additional
devices. Special attention must be paid to regulations about welding or drilling work
performed on structural parts.
• Observe the permissible ambient conditions of the DLT-U1100.
Power supply cable (detail view)
1
DLT-U1100 case
2
UPS connection cable <–> power source
on the vehicle
3
UPS connection cable <–> industrial PC
4
Phoenix contact plug and ground cable
for industrial PC
5
Cables with wires for the power source
on the vehicle
6
Direct current input from the power
source at the vehicle
7
Direct current output to the industrial PC
Required components
Pins input / output