background image

4

Mounting position on the vehicle

6

Mechanical and electrical mounting

Electrical connection points on the vehicle
The electrical connection point suitable for the DLT-U1100 depends on the respective 

vehicle type.

•  Make sure to observe the technical/electrical information of the vehicle manufacturer. 
•  Keep in mind that certain electrical connection points are not suitable for the  

   DLT-U1100, e.g. for vehicles with braking energy reclamation.
•  Position the DLT-U1100 as closely as possible to the connection point and  

   connect it there.
•  Make sure that the connection point exhibits a stable potential level.
•  Do not connect the DLT-U1100 directly to the circuit of high power consumption  

   devices (e.g. converters for forklift drives); this may result in sudden restarts,  

   malfunctions or damage to the device.
•  With some vehicles, the chassis represents DC+. The DLT-U1100 chassis is then also 

   DC+. If peripheral devices now supply DC-, e.g. via a plug connector through a serial 

   interface to the shield connection of the DLT-U1100, a short circuit is inevitable and 

   malfunctions/total failures are unavoidable.
•  It must be ensured with these vehicles that the UPS case does not have any electrical 

   connection to the vehicle body.

5

Electrical connection data

7

Contact

Advantech-DLoG 

  service@dlog.com 

 

 

Industriestraße 

15 

  www.advantech-dlog.com 

D-82110 Germering 

 

 

Telefon: (+49) 89 / 41 11 91 - 999

Quickstart Guide DLT-U1100 V1.00      DAN 885196E     01/30/2014 

Copyright 2014 by DLoG GmbH, Industriestraße 15, D-82110 Germering  

All rights reserved. Information in this document is subject to change without prior notice.

 

DLT-U1100 dimensions (in mm)

Mounting steps

•  Mount the DLT-U1100  

1

  on the vehicle via the two mounting brackets 

   and four M3.5x6 mm threaded screws.
•  Connect the connection cable  

2

  to the electrical connection point of the vehicle.

•  Connect with the DLT-U1100 (input) as shown in position  

6

 .

•  Connect connection cable  

3

  to the industrial PC. 

•  For this purpose, plug the Phoenix contact plug  

4

  into the UPS connection of the 

   industrial PC and screw tight.
•  Connect and fasten the ground cable to the ground pin of the industrial PC.
•  Connect with the UPS (output) as shown in position  

7

  .

•  Fasten all cables securely.

1

2

3

4

5

6

7

Mounting brackets 

with 2 drill holes 

for M3.5x6 mm 

threaded screws

Suitable mounting position

•  Take the permissible working temperature range of the DLT-U1100 into account  

   (heat development of the vehicle, e.g. near the engine).
•  The UPS DLT-U1100 heats up during the charging process; for this reason, make sure  

   to provide for adequate ventilation. Do not cover the UPS.
•  Check the available cable length. Both the electronic connection point of the vehicle  

   and the industrial PC must be easily reached.
•  Install the cables according to the regulations. Cables must not interfere with the ongoing 

   operation or present a hazard to persons.
•  Screw the cables sufficiently tight but make sure not to pinch them. Otherwise, the cable 

   may break or the cable insulation may be damaged.
•  Observe the specifications of the vehicle manufacturer for the attachment of additional 

   devices. Special attention must be paid to regulations about welding or drilling work 

   performed on structural parts.
•  Observe the permissible ambient conditions of the DLT-U1100.

Power supply cable (detail view)

1

DLT-U1100 case

2

UPS connection cable <–> power source 

on the vehicle

3

UPS connection cable <–> industrial PC

4

Phoenix contact plug and ground cable 

for industrial PC

5

Cables with wires for the power source 

on the vehicle

6

Direct current input from the power 

source at the vehicle

7

Direct current output to the industrial PC

Required components

Pins input / output