9
Integrated UPS and battery pack
The DLT-V4108 has an integrated uninterrupted power supply (UPS). The battery pack (lithium-ion
technology) of the UPS is located inside of back cover and couldn’t be changed by user.
WARNING
Personal injury due to short-circuit, fire, chemical burns, toxic substances.
The integrated UPS contain lithium-ion battery packs. These can ignite if the DLT-V4108 is handled or
stored improperly (risk of fire), cause chemical burns or release toxic substances.
Use care when handing the DLT-V4108.
Do not damage the DLT-V4108; otherwise lithium-ion battery packs could be damaged.
Do not allow the DLT-V4108 to come into contact with fire.
Performance specifications Li-ion rechargeable battery pack; 2 cells of UR14650R (900 mAh)
Bridging time
Typically 15 minutes (when battery pack is fully charged)
Charging time
2 h (fully recharge a completely discharged battery pack)
UPS charging temperature
0 to +45 °C (ambient temp.)
UPS discharging temperature
-20 to + 50 °C
Output power
6.48 W
Battery voltage
7.2 V