6. Electrical installation, cable connection, cable cover
6.1. Safety notice – observe before connecting
6.1.1.
General
WARNING
Risk of injury and damage due to improper electrical installation.
These instructions are directed to skilled personnel.
Only qualified skilled personnel are permitted to perform the electrical
installation of DLT-V6210.
Comply with the appropriate national installation regulations for all cable
routing.
6.1.2.
Installing the disconnecting device
WARNING
Electrical shock due to lack of disconnecting device.
DLT-V6210 industrial PCs are not equipped with disconnecting devices that are accessible from
outside; they do not have switches.
To enable the devices to be quickly disconnected from the power supply in emergency
situations:
Install an easily accessible disconnecting device such as a switch close to
the device.
Make sure that the disconnecting device disconnects all power supply lines.
WARNING
Deployment location in fueling stations, chemical plants.
The operation of electrical equipment at locations where flammable gases or vapors are present
poses a safety hazard.
Turn off DLT-V6210 when you are near gas stations, fuel depots, chemical
plants or places where blast might take place.