NOTICE: Physical damage
Observe the potential ratios.
On DLT-V6210, logic ground and shield ground are firmly connected to each other.
Logic ground is the ground (GND) used to supply the internal parts and components such as the
display or CPU. All cable shields and the housing are connected to shield ground.
The chassis of some forklifts is on DC+. This means that DLT-V6210 chassis is also on DC+.
Short circuits can arise when, for example, the ground potential of a peripheral device is on DC-.
This may cause malfunctions or irreparable damage to DLT-V6210.
Always attach the ring tongue of the power supply cable to the provided
ground bolt situated on the connector panel.
The other end of the yellow-green power supply cable must be connected to
the targeted object’s chassis.
Connect the power supply cable of DLT-V6210 as directly as possible to the
battery and not to the power supply lines (e.g. the engine power supply)
which a great deal of interference or otherwise affected by consumers.
Connecting DLT-V6210 to large electrical loads, such as converters for the
forklift motor may result in random restarts, malfunctions and/or irreparable
damage to the device.
If you want to connect devices fed by other power sources to DLT-V6210
(e.g. printers), be sure to power up the peripheral devices at the same time
or after DLT-V6210; otherwise, you may encounter start-up problem,
malfunctions or even irreparable damage to the device.
6.3.1.
Plugging in and screwing on the power supply cable
Fig. 6.2: The power supply cable secured and inserted in rubber seal
Plug the power supply cable into the
power supply plug-in location.
Tighten both mounting screws hand-
tight.
Fold-open the round cable passage in
the rubber seal.
Insert the power supply cable.