TABLE 11
: RS-232 MENU ITEM DEFINITION (continued)
Item
Description
Faults
Provides the fault messages and the normal status message:
1. OvrTemp (high temperature, over 85
°
C)
2. HPAL (left high power amplifier fault, or single high power PA fault)
3. HPAR (right high power amplifier fault)
4. PA (driver or single PA fault)
5. VSWR (high reflected power fault – reflected power is higher than
(P1dB-6 dB))
6. LOW_PWR (output power is under the set threshold, if the low power
condition is set as a fault)
7. L-RF (L-RF up-converter module failure).
8. OK (SSPB unit has no FAULT).
Alarms
1. Temp (temperature alarm - hot spot temperature exceeds 75 ºC)
2. HPAL (left high power amplifier alarm, or single high power PA alarm)
3. HPAR (right high power amplifier fault)
4. PA (driver or single PA fault)
5. LOW_PWR (output power is under the set threshold, if the low power
condition is set as a alarm)
6. Curr (current consumption exceeds the set threshold)
7. OVD (overdrive alarm – detected output power exceeds 51.0 dBm)
8. TXSWALM (transmission switch alarm)
9. +12V (power supply voltage out of pre-set low and high limits)
10. ALCL (ALC low – the target power for ALC is set too low)
11. ALCH (ALC high – the target power for ALC is set too high)
12. ALCS (ALC process was suspended)
13. OK (SSPB unit has no ALARM).
Tx WGSW
Transmission Waveguide position (on-line or stand by) – N/C (not
connected) for single unit
37