background image

ACP-2000 User Manual

/ 用户手册 / 用戶手冊

22

4.1

Getting Started

/ 入门指南 / 入門指南

Configuring the Intelligent System Module

An Intelligent System Module comes pre-installed inside your system chassis. The

hardware switch  will  be  fine  tuned  according  to  your  system  layout.  With  different

system  layouts,  we  can  configure  Intelligent  System  Modules  via  the  H/W  switch.

Please  refer  to  the  “Switch  Settings”  section  for  detailed  information.  For  remote

management  functions,  you  will  need  to  install  WISE-DeviceOn. After  installation

you will be able to monitor the system’s fan speed, system temperature, CPU tem

-

perature, and voltage. You can also set your own alarm settings under WISE-Devi

-

ceOn according to your requirements.  For detailed information, please refer to the

user guide for WISE-DeviceOn.

配置智能系统模块
智能系统模块已经预安装在系统机箱内。用户可根据不同的系统布局微调硬件开关。
有关详细信息,请参考 “ 开关设置 ”。对于远程管理功能,用户需安装 WISE-DeviceOn
才能监控系统风扇转速、系统温度、CPU 温度和电压。用户也可根据特定需求在 WISE-
DeviceOn 中调整报警设置。有关详细信息,请参考 “WISE-DeviceOn

 

用户指南 ”。

配置智慧系統模組
智能系統模組會預先安裝在系統機箱中。硬體的開關也會根據系統需求做調整。根據
不同的系統狀態,智能系統模組可以經由調整跳線開關來更改設定。用戶可以通過安
裝 WISE-DeviceOn 遠端管理系統的系統風扇速度、系統溫度、CPU 溫度、電壓等相關訊
息。同時客戶也能在 WISE-DeviceOn 中調整系統的告警標準。 更多詳細訊息請參考
WISE-DeviceOn 使用手冊。

4.2

Specifications

/ 规格 / 規格

4.2.1

Hardware Specifications

/ 硬件规格 / 硬體規格

1 x 10-pin hardware switch to configure alarm settings

1 x SMBus interface for system and main board health status monitoring

Up to 4 external temperature sensors

7 x Fan tachometer inputs

1 x External IPMI module connector

1 x Built-in buzzer for system health status notice

Automatic smart fan control

Reserved PCB layout for gravity and humidity sensor

1 x 用于配置报警设置的 10 针硬件开关

1 x 用于监控系统和主板健康状态的 SMBus 

多达 4 个外置温度传感器

7 x 风扇转速计输入

1 x 外置 IPMI 模块接口

1 x 用于提示系统健康状态的内置蜂鸣器

自动智能风扇控制

PCB 布局上预留重力和湿度传感器

Summary of Contents for ACP-2000

Page 1: ...User Manual ACP 2000 2U Rackmount Chassis with alarm notification functions 2U 2U...

Page 2: ...formation provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties that m...

Page 3: ...ck 14 Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel 15 If any of the following occurs have the equipment checked by service person nel...

Page 4: ...ssional technician please contact the service tech nician or your retailer if you need this service 24 Repair of the device may only be carried out by trained service personnel Advantech recommends th...

Page 5: ...watch the monitor or display over 1 hour each day 37 If user does not follow the instructions to set up the equipment there is a risk of opening the vent on the bottom side of the equipment The vent...

Page 6: ...ACP 2000 User Manual vi 1 2 3 18 FCC 15 1 2 19 20 21 22 1 23 VESA VESA 24 25 26 27 28 29 30 31 32 33 34 35 36 37 1 30 2 2 2 1 38 CLASS I LASER PRODUCT KLASS I LASER PRODUKT...

Page 7: ...vii ACP 2000 User Manual 1 2 3 4 5 6 7 0 C 32 F 40 C 122 F 8 9 10 11 12 13 14 15 16 17 IEC 60825 1 EN60825 1 1 2 3 18 FCC 15 1 2 19 20 CLASS I LASER PRODUCT KLASS I LASER PRODUKT...

Page 8: ...ACP 2000 User Manual viii 21 22 1 23 VESA VESA 24 25 26 27 28 29 30 31 32 33 34 35 36 37 1 30 2 2 2 1 38 www advantech com tw 26 20 1 886 2 7732 3399...

Page 9: ...best performance possible from your products If you run into technical difficulties we are here to help For the most frequently asked questions you can easily find answers in your product documentatio...

Page 10: ...te rials service time and freight Please consult your dealer for more details If you believe your product is defective follow the steps outlined below 1 Collect all the information about the problem e...

Page 11: ...xi ACP 2000 User Manual 3 RMA Return Material Authorization 4 5 RMA 1 CPU 2 3 RMA Return Mate rial Authorization 4 5 RMA...

Page 12: ...e carefully inspected the ACP 2000 mechanically and electrically before shipment It should be free of marks and scratches and in perfect working order upon receipt As you unpack the ACP 2000 check it...

Page 13: ...CPU CPU 10 Figure 2 5 Installing the Add on Card 11 2 4 Installing Disk Drives 11 Figure 2 6 Removing the Drive Bay 11 Figure 2 7 Assemble the HDD or Slim ODD 12 Figure 2 8 Assemble the HDD or ODD 12...

Page 14: ...nnectors and Switch Settings 26 Table 4 2 Hardware Switch 26 Table 4 3 Connectors 26 Table 4 4 SW1 3 27 Table 4 5 SW4 6 27 Table 4 6 SW7 9 27 Table 4 7 SW10 27 4 4 Board Layout 28 Figure 4 1 Connector...

Page 15: ...Chapter 1 1 General Information...

Page 16: ...2000 2U CT ACP 2000 e server 2U ACP 2000 19 2U IPC ACP 2000 2U CT ACP 2000 e server 2U 1 2 Specifications Construction Heavy duty steel Disk Drive Capacity One slim type ODD and two 3 5 disk drives Co...

Page 17: ...19 x 3 5 x 17 8 11 3 kg 25 3 lbs 1 3 Power Supply Options Table 1 1 Power supply options Type Single PS 2 power supply Watt 250W ATX 300W ATX 500W ATX Input rating 100 240Vac 90 264Vac 100 240Vac Out...

Page 18: ...Environmental specifications Environment Operating Non operating Temperature 0 40 C 32 104 F 20 60 C 4 140 F Humidity 10 to 85 40 C 104 F non condensing 10 to 95 40 C 104 F non condensing Vibration 0...

Page 19: ...5 ACP 2000 User Manual Chapter 1 General Information 1 5 Dimension Diagram Figure 1 1 Dimensions Diagram unit mm inch...

Page 20: ...ACP 2000 User Manual 6...

Page 21: ...Chapter 2 2 System Setup...

Page 22: ...er to the Appendix A Exploded Diagram for detailed part names A A 2 1 Removing the Top Cover Figure 2 1 Removing the Top Cover Note Use caution when installing or operating the components with the cha...

Page 23: ...3 express backplane ACP 2000P4 ACP 2000EBP ACP 2000P4 ACP 2000EBP Figure 2 2 Removing the System Cage Note Use caution when installing a motherboard We highly recommend choosing a CPU cooler listed o...

Page 24: ...ACP 2000 User Manual 10 Figure 2 3 Installing the Backplanes 2 3 Installing CPU Cards and Add on Cards CPU Card CPU Card Figure 2 4 Installing a CPU Card CPU CPU...

Page 25: ...11 ACP 2000 User Manual Chapter 2 System Setup Figure 2 5 Installing the Add on Card 2 4 Installing Disk Drives Figure 2 6 Removing the Drive Bay...

Page 26: ...ACP 2000 User Manual 12 Figure 2 7 Assemble the HDD or Slim ODD Figure 2 8 Assemble the HDD or ODD 2 5 Installing the Power Supply Figure 2 9 Installing the Power Supply...

Page 27: ...System Setup 2 6 Assembling the Handle and Brackets There is a pair of brackets and a pair of handles in the accessory box Assemble these parts on the chassis as demonstrated in the image below Figure...

Page 28: ...ACP 2000 User Manual 14...

Page 29: ...Chapter 3 3 Operation...

Page 30: ...oor cover with a key lock LED USB PS 2 LED USB PS 2 Figure 3 1 Front View With Door Closed Figure 3 2 Front View With Door Open 3 1 1 Switch Button and I O Interfaces I O I O ATX Power Switch Press th...

Page 31: ...he system power is on the power LED will turn Green A RED fan LED indicates a failed cooling fan In such cases the alarm will activate To stop the alarm s beeping press the Alarm Reset button and then...

Page 32: ...31 F An audible alarm will be activated To stop the alarm s beeping press the Alarm Reset button Inspect the fan filter and the rear section of the chassis immediately Make sure the airflow inside the...

Page 33: ...19 ACP 2000 User Manual Chapter 3 Operation 3 2 Replacing the Cooling Fan Figure 3 4 Removing the Fan Module Figure 3 5 Replacing the Cooling Fan...

Page 34: ...ACP 2000 User Manual 20 3 3 Replacing the Fan Filter Figure 3 6 Replacing the Fan Filter Figure 3 7 Replacing Front Door Filter...

Page 35: ...Chapter 4 4 Intelligent System Module...

Page 36: ...emperature CPU tem perature and voltage You can also set your own alarm settings under WISE Devi ceOn according to your requirements For detailed information please refer to the user guide for WISE De...

Page 37: ...puts 5 VDC 5 VDC 5 VSB 3 3 VDC 12 VDC 12 VDC Temperature Sensors LM75 digital temperature sensor I2C interface 30 125 C 22 257 F Fan Speed Monitor Up to 7 fans Power Monitoring Detect Redundant power...

Page 38: ...AN speed temperature monitoring Remote system monitoring through WISE DeviceOn Alarm on board buzzer and LED signal WISE DeviceOn LED CPU WISE DeviceOn LED 4 2 5 WISE DeviceOn Management Function WISE...

Page 39: ...SI command to search IPMI SUSI IPMI SUSI Blinking Warm keep beep HDD Normal Normal Data transferring Blinking FAN Normal 500rpm Normal CPU fan fail CPU CPU 500rpm Warm keep beep System fan fail 500rpm...

Page 40: ...e Connector SMBus SMBus BZ1 External Buzzer Connector Buzzer HDD1 HDD LED connector HDD LED LED PWR1 PSU Power Connector PSU SMB_MB1 I2C or SNMP connector I2C SNMP I2C SNMP RDUPG1 Power Good Input Con...

Page 41: ...ON OFF ON Connect 2 2 ON ON OFF Connect 3 1 ON ON ON Connect 3 2 Table 4 5 SW4 6 SW1 Pin4 SW1 Pin5 SW1 Pin6 SYS FAN Qty OFF OFF OFF Disable OFF OFF ON 1 FAN1 OFF ON OFF 2 FAN1 2 OFF ON ON 3 FAN1 3 ON...

Page 42: ...C_SCLK Pin 2 I2C_SDAT Table 4 9 IPMB1 Pin 1 NC Pin 3 S_SDAT_R Pin 2 S_SCLK_R Pin 4 GND Table 4 10 PMBUS1 Pin 1 V_PMBUS Pin 4 I2C_SDAT Pin 2 GND Pin 5 I2C_SCLK Pin 3 NC Table 4 11 SMB_3V_1 Pin 1 V_SMB...

Page 43: ...Pin 2 GND Pin 6 V3 3 Pin 3 GND Pin 7 V12 Pin 4 V5 Pin 8 V12 Table 4 15 TR1 4 Pin 1 TEMP_SEN1 4 Pin 2 GND Table 4 16 RDUPG1 Pin 1 GND Pin 2 PWR_FAIL_IN Table 4 17 BZ1 Pin 1 V5_DUAL Pin 2 EXT_BUZZ Table...

Page 44: ...ACP 2000 User Manual 30...

Page 45: ...Appendix A A Exploded Diagram...

Page 46: ...ACP 2000 User Manual 32 A 1 Exploded Diagram Figure A 1 Exploded Diagram...

Page 47: ...33 ACP 2000 User Manual Appendix A Exploded Diagram...

Page 48: ...without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion from the publisher All brand...

Reviews: