Lab
Report No.: 0609083 Rev. 1
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325
Accredited Lab. Of BSMI, NEMKO, NVLAP
Page 41 of 59
Listed Lab. of AUSTEL, Commerce, FCC, VCCI
NVLAP Lab Code:200085-0
12. VOLTAGE DIPS AND SHORT INTERRUPTIONS TEST
12.1 TEST EQUIPMENT
Item
Instrument
Manufacturer
Model
Serial No. Last Cal. Date
1
ULTRA COMPACT
GENERATOR
EM TEST
UCS 500-M
0500-15
07/10/04
Note: All equipment upon which need to be calibrated are with calibration period of 1 year.
12.2 TEST METHOD
According to
EN 55024:1998 + A1: 2001 + A2: 2003
IEC 61000-4-11: 1994 + A1: 2001
12.3 BLOCK DIAGRAM OF TEST SETUP
Note: This is a reprehensive setup diagram for Table-top EUT.
For Floor-standing EUT, the table will be removed with all others setup condition remain the same.
12.4 SEVERITY LEVELS
Voltage Dips and
Interruption
Reduction(%)
Test Duration
Required Performance
Criteria
>95 10
ms
B
30 500
ms
C
>95 5s
C
12.5 OPERATING CONDITIONS OF THE EUT
1. Setup the EUT and Test Equipment as shown on 12.3.
2. Power on the EUT. Acting performance checking program to allow EUT executing its usual
operation mode during test.
12.6 TEST PROCEDURE
The EUT and its load were placed on a table which was 0.8 meters height.
For AC Power line test:
The EUT was connected to the power mains through a coupling device that directly couples
to the Voltage Dips and Interruption Generator.
Voltage dips of >95% for 10ms and 30% for 500ms were applied to the EUT three times with
10 sec intervals between dips. A power interruption of 100% for 5000ms (5 sec) was applied
to the EUT three times with 60-second intervals between interruptions.
Voltage Dips/
Interruptions
/Variations
Simulator
EUT
Load
To AC
Line
Controller Computer
Shield Room
Non-Conducted Table
80cm
AC Power Line to EUT